Lightning risk assessment of active distribution network with distributed photovoltaic system

Lightning strikes are the main reason for the fault of active distribution network. It is of great significance to study the risk assessment of lightning in active distribution network for lightning protection. Taking an active distribution network in a certain region as the research object, considering the mutual influence between the photovoltaic side and the distribution line side during lightning strikes, the method of lightning risk assessment for the active distribution network with photovoltaic system was proposed. Electrical geometric models were constructed to calculate the fault rate of the photovoltaic side and the trip rate of the distribution line side, and the risk assessment was conducted based on the calculation results. The results show that when the lightning strike is closest to the tower on the photovoltaic side, the lightning fault rate on the photovoltaic side increases from 0.957 times/year to 3.0766 times/year. When the photovoltaic side is struck by lightning, the intrusion of lightning impulse can double the lightning trip rate of the adjacent three towers on the distribution line side, indicating a higher risk level. It is recommended to focus on the protection measurement for the three towers near the photovoltaic system.

Authors

Institutions

Publication Details

Journal
Energy Reports
Published
2024-09-28
DOI
https://doi.org/10.1016/j.egyr.2024.09.045
Citations
4
Primary Topic
Lightning and Electromagnetic Phenomena
Type
article
Field-Weighted Citation Impact
1.33
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Lightning risk assessment of active distribution network with distributed photovoltaic system

Jing Liu, Lingzhi Xia, Chen Chai, Yushun Liu et al.
4 citations
Energy Reports
Lightning and Electromagnetic Phenomena
1.33
article

Lightning risk assessment of active distribution network with distributed photovoltaic system

Jing Liu, Lingzhi Xia, Chen Chai, Yushun Liu, Peng Li, Mingxiang Zhang
article en
4 citations

Abstract

Lightning strikes are the main reason for the fault of active distribution network. It is of great significance to study the risk assessment of lightning in active distribution network for lightning protection. Taking an active distribution network in a certain region as the research object, considering the mutual influence between the photovoltaic side and the distribution line side during lightning strikes, the method of lightning risk assessment for the active distribution network with photovoltaic system was proposed. Electrical geometric models were constructed to calculate the fault rate of the photovoltaic side and the trip rate of the distribution line side, and the risk assessment was conducted based on the calculation results. The results show that when the lightning strike is closest to the tower on the photovoltaic side, the lightning fault rate on the photovoltaic side increases from 0.957 times/year to 3.0766 times/year. When the photovoltaic side is struck by lightning, the intrusion of lightning impulse can double the lightning trip rate of the adjacent three towers on the distribution line side, indicating a higher risk level. It is recommended to focus on the protection measurement for the three towers near the photovoltaic system.

Energy ReportsVol. 12
Electric Power Research Institute (US), China Three Gorges University (CN), China Power Engineering Consulting Group (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 19%
Lightning and Electromagnetic Phenomena
1.33
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Lightning risk assessment of active distribution network with distributed photovoltaic system — Jing Liu, Lingzhi Xia, et al. · Energy Reports (2024) | TGRS Research Map | TGRS