Circulation of self-supplied water for significant energy recovery through heat integration

• • An overhead heat-integrated distillation column (OHIDiC) was newly proposed. • • Overhead vapor undergoes direct heat exchange with both the feed and product water. • • Higher overhead vapor temperature showed larger reduction in the total heat duty. • • The circulating product water provides continuous cooling and drives forward reaction. • • Decrease in the energy reduction led to significant CO 2 emission and cost reduction. This study introduces an overhead heat-integrated distillation column (OHIDiC), a novel approach that maximizes heat recovery by multiple heat exchanges and product circulation. By utilizing the overhead vapor as a direct heat source, low-temperature feed and product water were used as cooling agents, thereby significantly reducing the condenser duty and reliance on cooling utilities. Additionally, the heated feed transfers heat to the column, leading to a substantial reduction of reboiler heat duty. Some of the heated product water is recycled back to the decanter for product cycling, while the rest is released as the final product. This circulation process ensures a continuous coolant supply, which contributes the reduction of condenser duty. Two processes were considered in this study, utilizing the water product from a non-reactive, and from a reactive separation within the system. When applied to the separation of a water-dodecanol mixture, OHIDiC reduced the condenser duty by 69.21% compared to a traditional distillation column, with a 31.46% reduction in the total utility consumption. When reactive distillation was incorporated into the OHIDiC, the higher overhead vapor temperature facilitated high heat transfer in the multiple heat exchange sections, thereby significantly reducing the total thermal load. This resulted in a reduction of up to 46.96% in total heat duty and a 36.06% decrease in CO 2 emissions. These findings confirm that the OHIDiC achieves significant energy savings through the utilization of process-derived substances, with pronounced benefits when the temperature of the overhead vapor becomes higher.

Authors

Institutions

Publication Details

Journal
Energy Conversion and Management X
Published
2024-09-28
DOI
https://doi.org/10.1016/j.ecmx.2024.100740
Citations
6
Primary Topic
Process Optimization and Integration
Type
article
Field-Weighted Citation Impact
1.97

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Circulation of self-supplied water for significant energy recovery through heat integration

Minyong Lee, Jeongwoo Lee, Yongbeom Shin, Jae Wook Lee et al.
6 citations
Energy Conversion and Management X
Process Optimization and Integration
1.97
article

Circulation of self-supplied water for significant energy recovery through heat integration

Minyong Lee, Jeongwoo Lee, Yongbeom Shin, Jae Wook Lee, Donggun Kim
article en
6 citations

Abstract

• • An overhead heat-integrated distillation column (OHIDiC) was newly proposed. • • Overhead vapor undergoes direct heat exchange with both the feed and product water. • • Higher overhead vapor temperature showed larger reduction in the total heat duty. • • The circulating product water provides continuous cooling and drives forward reaction. • • Decrease in the energy reduction led to significant CO 2 emission and cost reduction. This study introduces an overhead heat-integrated distillation column (OHIDiC), a novel approach that maximizes heat recovery by multiple heat exchanges and product circulation. By utilizing the overhead vapor as a direct heat source, low-temperature feed and product water were used as cooling agents, thereby significantly reducing the condenser duty and reliance on cooling utilities. Additionally, the heated feed transfers heat to the column, leading to a substantial reduction of reboiler heat duty. Some of the heated product water is recycled back to the decanter for product cycling, while the rest is released as the final product. This circulation process ensures a continuous coolant supply, which contributes the reduction of condenser duty. Two processes were considered in this study, utilizing the water product from a non-reactive, and from a reactive separation within the system. When applied to the separation of a water-dodecanol mixture, OHIDiC reduced the condenser duty by 69.21% compared to a traditional distillation column, with a 31.46% reduction in the total utility consumption. When reactive distillation was incorporated into the OHIDiC, the higher overhead vapor temperature facilitated high heat transfer in the multiple heat exchange sections, thereby significantly reducing the total thermal load. This resulted in a reduction of up to 46.96% in total heat duty and a 36.06% decrease in CO 2 emissions. These findings confirm that the OHIDiC achieves significant energy savings through the utilization of process-derived substances, with pronounced benefits when the temperature of the overhead vapor becomes higher.

Energy Conversion and Management XVol. 24
Korea Advanced Institute of Science and Technology (KR)
National Research Foundation of Korea
Affordable and clean energy
Openalex Percentile: Top 13%
Process Optimization and Integration
1.97
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.