Fatigue Analysis of Nitinol Peripheral Artery Stents Under Complex Loads

Abstract The complex deformation of a peripheral arterial stent during limb movements is the main reason for its fatigue fracture. The aim of this study is to explore the impact of complex loads on the fatigue behavior and life of lower limb arterial stents. Specifically, the finite element simulation was adopted to compare and analyze the fatigue performance of three stents under five superimposed loads. Besides, the life and the fatigue crack growth life of these stents were predicted. It demonstrated that the bending load superimposed on other loads exerted a significant impact on the fatigue performance of these stents. The “spiral” structure design of the stent helped to improve the fatigue durability under complex deformations. Moreover, the prediction method for fatigue crack growth life is relatively conservative, which accounted for approximately 65–97% of the full life. The work provides important references for the fracture assessment and the optimization design of structure of stents.

Authors

Institutions

Publication Details

Journal
Journal of Medical Devices
Published
2024-09-28
DOI
https://doi.org/10.1115/1.4066698
Primary Topic
Shape Memory Alloy Transformations
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fatigue Analysis of Nitinol Peripheral Artery Stents Under Complex Loads

Yanlong Chen, Juan Su, Hailu Zhang, Lin Wang et al.
4 links
Journal of Medical Devices
Shape Memory Alloy Transformations
article

Fatigue Analysis of Nitinol Peripheral Artery Stents Under Complex Loads

Yanlong Chen, Juan Su, Hailu Zhang, Lin Wang, Haiquan Feng
article en

Abstract

Abstract The complex deformation of a peripheral arterial stent during limb movements is the main reason for its fatigue fracture. The aim of this study is to explore the impact of complex loads on the fatigue behavior and life of lower limb arterial stents. Specifically, the finite element simulation was adopted to compare and analyze the fatigue performance of three stents under five superimposed loads. Besides, the life and the fatigue crack growth life of these stents were predicted. It demonstrated that the bending load superimposed on other loads exerted a significant impact on the fatigue performance of these stents. The “spiral” structure design of the stent helped to improve the fatigue durability under complex deformations. Moreover, the prediction method for fatigue crack growth life is relatively conservative, which accounted for approximately 65–97% of the full life. The work provides important references for the fracture assessment and the optimization design of structure of stents.

Journal of Medical DevicesVol. 19(1)
Hebei University of Technology (CN), Lifetech Scientific (China) (CN), Inner Mongolia University of Technology (CN), Xingtai University (CN)
National Natural Science Foundation of China, Natural Science Foundation of Inner Mongolia
Openalex Percentile: Top 90%
Shape Memory Alloy Transformations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Fatigue Analysis of Nitinol Peripheral Artery Stents Under Complex Loads — Yanlong Chen, Juan Su, et al. · Journal of Medical Devices (2024) | TGRS Research Map | TGRS