A Comparative Evaluation of New and Used Dental Explorer Working Tips

Abstract The dental explorer medical device assists multiple functions, including marginal assessment. The working tip quality of this instrument has been previously established as a factor affecting operator judgment. However, little data exists to demonstrate the actual quality of working tips in clinical practice. The purpose of this study is to investigate and quantify if any real, measurable differences of the explorer working tip dimension exist among such instruments currently in service and compare to published medical device industry standards. Twenty new #23 dental explorer instruments from two manufacturers served as controls and sixty-three instruments in circulation at a dental school clinic were observed using light microscopy. The instruments were measured 50 micrometers from the terminus. A one-way analysis of variance (ANOVA) was performed to analyze values among groups. No statistically significant difference between the mean working tip dimension of new instruments was detected between brands. However, statistically significant differences between new and used instruments were detected regardless of brand. The range of values was 92.5–227.5 micrometers with average used instrument tip estimated over 50% wider than the average new instrument. These findings imply that other studies employing a dental explorer may be confounded if the instrument is not measured. Furthermore, the results of this study should serve as a motivating factor toward future research to update quality standards regarding the medical device with a goal of defining acceptable dimensions of the instrument working tip for certain applications in relation to clinical performance and expected outcomes.

Authors

Institutions

Publication Details

Journal
Journal of Medical Devices
Published
2024-09-28
DOI
https://doi.org/10.1115/1.4066699
Primary Topic
Dental Research and COVID-19
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Comparative Evaluation of New and Used Dental Explorer Working Tips

Arthur Valeri, Charlie Cage, Terrence Donovan
Journal of Medical Devices
Dental Research and COVID-19
article

A Comparative Evaluation of New and Used Dental Explorer Working Tips

Arthur Valeri, Charlie Cage, Terrence Donovan
article en

Abstract

Abstract The dental explorer medical device assists multiple functions, including marginal assessment. The working tip quality of this instrument has been previously established as a factor affecting operator judgment. However, little data exists to demonstrate the actual quality of working tips in clinical practice. The purpose of this study is to investigate and quantify if any real, measurable differences of the explorer working tip dimension exist among such instruments currently in service and compare to published medical device industry standards. Twenty new #23 dental explorer instruments from two manufacturers served as controls and sixty-three instruments in circulation at a dental school clinic were observed using light microscopy. The instruments were measured 50 micrometers from the terminus. A one-way analysis of variance (ANOVA) was performed to analyze values among groups. No statistically significant difference between the mean working tip dimension of new instruments was detected between brands. However, statistically significant differences between new and used instruments were detected regardless of brand. The range of values was 92.5–227.5 micrometers with average used instrument tip estimated over 50% wider than the average new instrument. These findings imply that other studies employing a dental explorer may be confounded if the instrument is not measured. Furthermore, the results of this study should serve as a motivating factor toward future research to update quality standards regarding the medical device with a goal of defining acceptable dimensions of the instrument working tip for certain applications in relation to clinical performance and expected outcomes.

Journal of Medical DevicesVol. 19(1)
University of North Carolina at Chapel Hill (US), Naval Medical Center San Diego (US), Captain James A. Lovell Federal Health Care Center (US), United States Department of the Navy (US), Great Lakes Institute of Management (IN)
Openalex Percentile: Top 69%
Dental Research and COVID-19
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Comparative Evaluation of New and Used Dental Explorer Working Tips — Arthur Valeri, Charlie Cage, et al. · Journal of Medical Devices (2024) | TGRS Research Map | TGRS