Design of modified long short-term memory-based zebra optimization algorithm for limiting the issue of SHEPWM in multi-level inverter

This research work proposes unique MLSTM-ZOA to quickly measure SAs for an MLI. Within a certain MI range, the suggested method may calculate a greater count of SAs with various solutions. Here, the main objective lies in minimizing the THD with consideration of three parameters such as MI, number of pulses per quarter cycle, and duty cycle. Furthermore, by achieving a lower fitness value in less iteration, the suggested method has definitely outperformed other methods with respect to convergence behavior, according to the data. Lastly, analysis and performance associated with the experimental validation of SHE in multi-level inverter are also carried out. The proposed MLSTM-ZOA model in terms of THD is 56.25%, 81.58%, 53.33%, and 41.67% better than MPA, HHO, MGMPA, and SF-BOA respectively. Similarly, the proposed MLSTM-ZOA model with respect to HDP is 64.03%, 47.16%, 84.01%, and 27.62% advanced than MPA, HHO, MGMPA, and SF-BOA respectively.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-09-28
DOI
https://doi.org/10.1038/s41598-024-73308-9
Citations
2
Primary Topic
Multilevel Inverters and Converters
Type
article
Field-Weighted Citation Impact
0.42

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design of modified long short-term memory-based zebra optimization algorithm for limiting the issue of SHEPWM in multi-level inverter

G. Krithiga, Mohammed Alharbi, S. P. Mangaiyarkarasi, S. Senthilkumar
2 citations
Scientific Reports
Multilevel Inverters and Converters
0.42
article

Design of modified long short-term memory-based zebra optimization algorithm for limiting the issue of SHEPWM in multi-level inverter

G. Krithiga, Mohammed Alharbi, S. P. Mangaiyarkarasi, S. Senthilkumar
article en
2 citations

Abstract

This research work proposes unique MLSTM-ZOA to quickly measure SAs for an MLI. Within a certain MI range, the suggested method may calculate a greater count of SAs with various solutions. Here, the main objective lies in minimizing the THD with consideration of three parameters such as MI, number of pulses per quarter cycle, and duty cycle. Furthermore, by achieving a lower fitness value in less iteration, the suggested method has definitely outperformed other methods with respect to convergence behavior, according to the data. Lastly, analysis and performance associated with the experimental validation of SHE in multi-level inverter are also carried out. The proposed MLSTM-ZOA model in terms of THD is 56.25%, 81.58%, 53.33%, and 41.67% better than MPA, HHO, MGMPA, and SF-BOA respectively. Similarly, the proposed MLSTM-ZOA model with respect to HDP is 64.03%, 47.16%, 84.01%, and 27.62% advanced than MPA, HHO, MGMPA, and SF-BOA respectively.

Scientific ReportsVol. 14(1)
National Institute of Food Technology, Entrepreneurship and Management - Thanjavur (IN), Govind Ballabh Pant University of Agriculture and Technology (IN), King Saud University (SA), Open International University for Alternative Medicines (IN), E.G.S. Pillay Engineering College
King Saud University
Affordable and clean energy
Openalex Percentile: Top 38%
Multilevel Inverters and Converters
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.