Design and Implementation of a Computer-Controlled Hybrid Oscillatory Ventilator

During mechanical ventilation, lung function and gas exchange in structurally heterogeneous lungs may be improved when volume oscillations at the airway opening are applied at multiple frequencies simultaneously, a technique referred to as multifrequency oscillatory ventilation (MFOV). This is in contrast to conventional high-frequency oscillatory ventilation (HFOV), for which oscillatory volumes are applied at a single frequency. In the present study, as a means of fully realizing the potential of MFOV, we designed and tested a computer-controlled hybrid oscillatory ventilator capable of generating the flows, tidal volumes, and airway pressures required for MFOV, HFOV, conventional mechanical ventilation (CMV), as well as oscillometric measurements of respiratory impedance. The device employs an iterative spectral feedback controller to generate a wide range of oscillatory waveforms. The performance of the device meets that of commercial mechanical ventilators in volume-controlled mode. Oscillatory modes of ventilation also meet design specifications in a mechanical test lung, over frequencies from 4 to 20 Hz and mean airway pressure from 5 to 30 cmH<sub>2</sub>O. In proof-of-concept experiments, the oscillatory ventilator maintained adequate gas exchange in a porcine model of acute lung injury, using combinations of conventional and oscillatory ventilation modalities. In summary, our novel device is capable of generating a wide range of conventional and oscillatory ventilation waveforms with potential to enhance gas exchange, while simultaneously providing less injurious ventilation.

Authors

Institutions

Publication Details

Journal
Journal of Medical Devices
Published
2024-09-28
DOI
https://doi.org/10.1115/1.4066679
Citations
1
Primary Topic
Respiratory Support and Mechanisms
Type
article
Field-Weighted Citation Impact
0.42

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Implementation of a Computer-Controlled Hybrid Oscillatory Ventilator

Jason H. T. Bates, David W. Kaczka, Monica L. Hawley, A. Fonseca Cruz et al.
1 citations
Journal of Medical Devices
Respiratory Support and Mechanisms
0.42
article

Design and Implementation of a Computer-Controlled Hybrid Oscillatory Ventilator

Jason H. T. Bates, David W. Kaczka, Monica L. Hawley, A. Fonseca Cruz, Jacob Herrmann, Donald Fox, Bakir Hajdarevic
article en
1 citations

Abstract

During mechanical ventilation, lung function and gas exchange in structurally heterogeneous lungs may be improved when volume oscillations at the airway opening are applied at multiple frequencies simultaneously, a technique referred to as multifrequency oscillatory ventilation (MFOV). This is in contrast to conventional high-frequency oscillatory ventilation (HFOV), for which oscillatory volumes are applied at a single frequency. In the present study, as a means of fully realizing the potential of MFOV, we designed and tested a computer-controlled hybrid oscillatory ventilator capable of generating the flows, tidal volumes, and airway pressures required for MFOV, HFOV, conventional mechanical ventilation (CMV), as well as oscillometric measurements of respiratory impedance. The device employs an iterative spectral feedback controller to generate a wide range of oscillatory waveforms. The performance of the device meets that of commercial mechanical ventilators in volume-controlled mode. Oscillatory modes of ventilation also meet design specifications in a mechanical test lung, over frequencies from 4 to 20 Hz and mean airway pressure from 5 to 30 cmH<sub>2</sub>O. In proof-of-concept experiments, the oscillatory ventilator maintained adequate gas exchange in a porcine model of acute lung injury, using combinations of conventional and oscillatory ventilation modalities. In summary, our novel device is capable of generating a wide range of conventional and oscillatory ventilation waveforms with potential to enhance gas exchange, while simultaneously providing less injurious ventilation.

Journal of Medical DevicesVol. 19(1)
University of Vermont (US), University of Iowa (US), Detector Technology (United States) (US)
National Institutes of Health
Openalex Percentile: Top 32%
Respiratory Support and Mechanisms
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.