Measurement of Steam-Generator-Tube Vibration Damping Caused by Anti-Vibration-Bar Supports

Abstract In 2013, Atomic Energy of Canada Limited (now Canadian Nuclear Laboratories) experimentally measured the damping of a straight tube with a variety of tube supports to examine low-frequency damping. These tests were motivated by the discovery of severe tube damage caused by in-plane fluidelastic instability (FEI) in the U-bend regions of new replacement recirculating steam generators (SG). The measurements were intended to assess the applicability of existing design guidelines for estimating the support-related damping of a tube. In the tests, the damping ratios of a single steam generator tube were measured using both log-decrement and power-based methods. Noncontacting excitation and position-sensing techniques were employed to improve accuracy. Initial baseline tests explored configurations with no support and drilled-hole supports of different hole sizes, and these results were compared with previously published work. Subsequent tests were performed to measure damping of tube vibration parallel to flat-bar supports. Most of the tests were performed with the tube fully submerged in still water. The tests examined the effects of fluid (water or air), natural frequency, gap width, preload, and vibration normal to the bars. This paper describes the test apparatus, methods, and analysis techniques. A summary of the results is presented. The initial baseline results showed that the damping ratios measured without any supports and with a drilled-hole support were consistent with previously published data. However, the subsequent measurements showed that, contrary to a published design guideline, the anti-vibration bars resulted in no significant additional viscous or squeeze-film damping when the vibration was parallel to the bars. On the other hand, the results did show that anti-vibration bars could introduce significant in-plane Coulomb-type damping if there was sufficient tube-to-support preload or impacting.

Authors

Institutions

Publication Details

Journal
Journal of Pressure Vessel Technology
Published
2024-09-28
DOI
https://doi.org/10.1115/1.4066674
Primary Topic
Engineering Diagnostics and Reliability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurement of Steam-Generator-Tube Vibration Damping Caused by Anti-Vibration-Bar Supports

Paul Feenstra, Michael C. Liu, Bruce Smith
Journal of Pressure Vessel Technology
Engineering Diagnostics and Reliability
article

Measurement of Steam-Generator-Tube Vibration Damping Caused by Anti-Vibration-Bar Supports

Paul Feenstra, Michael C. Liu, Bruce Smith
article en

Abstract

Abstract In 2013, Atomic Energy of Canada Limited (now Canadian Nuclear Laboratories) experimentally measured the damping of a straight tube with a variety of tube supports to examine low-frequency damping. These tests were motivated by the discovery of severe tube damage caused by in-plane fluidelastic instability (FEI) in the U-bend regions of new replacement recirculating steam generators (SG). The measurements were intended to assess the applicability of existing design guidelines for estimating the support-related damping of a tube. In the tests, the damping ratios of a single steam generator tube were measured using both log-decrement and power-based methods. Noncontacting excitation and position-sensing techniques were employed to improve accuracy. Initial baseline tests explored configurations with no support and drilled-hole supports of different hole sizes, and these results were compared with previously published work. Subsequent tests were performed to measure damping of tube vibration parallel to flat-bar supports. Most of the tests were performed with the tube fully submerged in still water. The tests examined the effects of fluid (water or air), natural frequency, gap width, preload, and vibration normal to the bars. This paper describes the test apparatus, methods, and analysis techniques. A summary of the results is presented. The initial baseline results showed that the damping ratios measured without any supports and with a drilled-hole support were consistent with previously published data. However, the subsequent measurements showed that, contrary to a published design guideline, the anti-vibration bars resulted in no significant additional viscous or squeeze-film damping when the vibration was parallel to the bars. On the other hand, the results did show that anti-vibration bars could introduce significant in-plane Coulomb-type damping if there was sufficient tube-to-support preload or impacting.

Journal of Pressure Vessel TechnologyVol. 147(1)
Intertek (Canada) (CA), Deep River Science Academy (CA), Intertek (United States) (US), Canadian Nuclear Laboratories (CA)
Openalex Percentile: Top 83%
Engineering Diagnostics and Reliability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.