Environmentally friendly molecularly imprinted polymers as an insert for SPE type columns in the gentamicin monitoring process

The quantity and variety of micro-pollutants infiltrating water resources have increased rapidly in recent times. The appearance of many harmful substances in the waters has resulted in so-called chemical cocktails which significantly contribute to the deterioration of water quality. Additionally, the variety of these compounds, often similar to each other in terms of molecular weights, makes their separation and identification very difficult. In this paper we present the possibility of using self-regenerating mechanism of molecularly imprinted polymers to measure the concentration of micropollutants in the aquatic environment. Molecularly imprinted polymers toward gentamicin were prepared by monomer polymerization in aqueous solution at ambient temperature. Results from computer-based molecular modelling demonstrated potential binding sites between gentamicin and functional monomers in water. Various compositions of polymerization mixtures were tested. The ratio of monomers to each other was 1.1:1.4:0.0015 and 1:1:1 for N-isopropylacrylamine:acrylamide:acrylic acid, respectively. For each composition, various amounts of the standard were tested: 0, 3, 5, 7, 10,15 mol% in relation to monomers. The best results were obtained for 5 % gentamicin with an excess of acrylamide in relation to the other monomers. Sorption for this system was 0.783 mg/g at ambient temperature and desorption 0.593 at 4 °C. The synthesized materials, thanks to the incorporation of thermosensitive poly(N-isopropylacrylamide) into their structures, were able to release 89 % of adsorbed gentamicin. This made it possible to use the designed SPE columns repeatably with similar efficiency. The prepared materials were selective in the presence of other antibiotics like amoxicillin and norfloxacin.

Authors

Institutions

Publication Details

Journal
Talanta
Published
2024-09-27
DOI
https://doi.org/10.1016/j.talanta.2024.126966
Citations
10
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
2.36

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Environmentally friendly molecularly imprinted polymers as an insert for SPE type columns in the gentamicin monitoring process

Marek Bryjak, Todd Cowen, Katarzyna Smolińska-Kempisty, Julia Duda
10 citations
Talanta
Analytical chemistry methods development
2.36
article

Environmentally friendly molecularly imprinted polymers as an insert for SPE type columns in the gentamicin monitoring process

Marek Bryjak, Todd Cowen, Katarzyna Smolińska-Kempisty, Julia Duda
article en
10 citations

Abstract

The quantity and variety of micro-pollutants infiltrating water resources have increased rapidly in recent times. The appearance of many harmful substances in the waters has resulted in so-called chemical cocktails which significantly contribute to the deterioration of water quality. Additionally, the variety of these compounds, often similar to each other in terms of molecular weights, makes their separation and identification very difficult. In this paper we present the possibility of using self-regenerating mechanism of molecularly imprinted polymers to measure the concentration of micropollutants in the aquatic environment. Molecularly imprinted polymers toward gentamicin were prepared by monomer polymerization in aqueous solution at ambient temperature. Results from computer-based molecular modelling demonstrated potential binding sites between gentamicin and functional monomers in water. Various compositions of polymerization mixtures were tested. The ratio of monomers to each other was 1.1:1.4:0.0015 and 1:1:1 for N-isopropylacrylamine:acrylamide:acrylic acid, respectively. For each composition, various amounts of the standard were tested: 0, 3, 5, 7, 10,15 mol% in relation to monomers. The best results were obtained for 5 % gentamicin with an excess of acrylamide in relation to the other monomers. Sorption for this system was 0.783 mg/g at ambient temperature and desorption 0.593 at 4 °C. The synthesized materials, thanks to the incorporation of thermosensitive poly(N-isopropylacrylamide) into their structures, were able to release 89 % of adsorbed gentamicin. This made it possible to use the designed SPE columns repeatably with similar efficiency. The prepared materials were selective in the presence of other antibiotics like amoxicillin and norfloxacin.

TalantaVol. 282
Wrocław University of Science and Technology (PL), University of Verona (IT), Nicolaus Copernicus University (PL), AGH University of Krakow (PL)
Narodowe Centrum Nauki, Narodowym Centrum Nauki
Life in Land
Openalex Percentile: Top 12%
Analytical chemistry methods development
2.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.