Establishment of Preanalytical Quality Indicators and Current Status of Preanalytical Phase Laboratory Performance Monitoring in the Clinical Laboratories in Korea

Background:The preanalytical phase is more vulnerable to errors.This study aimed to establish preanalytical quality indicators (QIs) suitable for Korean clinical laboratories and investigate the current status of preanalytical phase performance monitoring in Korea using these QIs.Methods: We reviewed previous studies investigating preanalytical QIs including the International Federation of Clinical Chemistry (IFCC) model of QIs, to establish a set of QIs for Korean clinical laboratories.An e-mail survey consisting of this QI set was sent to 90 clinical laboratories.The collected data were analyzed, and performance measures were evaluated according to the quality specifications defined by the IFCC and the sigmascale method.Results: A model consisting of 23 preanalytical phase QIs was established.Approximately 47% (42/90) of clinical laboratories responded to the survey.The average result submission rate for each QI was 56% (standard deviation, 26%).The QIs with the highest and lowest result submission rates were "rejected samples due to hemolysis" (95%) and "recollected sample due to errors caused outside the laboratory" (17%).The QIs with the highest and lowest error rates were "hemolyzed sample detected by hemolytic index" (median, 0.546%; sigma performance level, "good") and "samples not received" (median, 0.001%; sigma performance level, "very good"), respectively.Conclusions: This survey findings on preanalytical phase QIs could serve as a foundation for developing an external quality assessment program for clinical laboratories in Korea.

Authors

Institutions

Publication Details

Journal
Journal of Laboratory Medicine and Quality Assurance
Published
2024-09-27
DOI
https://doi.org/10.15263/jlmqa.2024.46.3.145
Primary Topic
Meta-analysis and systematic reviews
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Establishment of Preanalytical Quality Indicators and Current Status of Preanalytical Phase Laboratory Performance Monitoring in the Clinical Laboratories in Korea

Kyunghoon Lee, Hyung‐Doo Park, Sollip Kim, Yong-Wha Lee et al.
Journal of Laboratory Medicine and Quality Assurance
Meta-analysis and systematic reviews
article

Establishment of Preanalytical Quality Indicators and Current Status of Preanalytical Phase Laboratory Performance Monitoring in the Clinical Laboratories in Korea

Kyunghoon Lee, Hyung‐Doo Park, Sollip Kim, Yong-Wha Lee, Sail Chun, Sangmi Kim
article en

Abstract

Background:The preanalytical phase is more vulnerable to errors.This study aimed to establish preanalytical quality indicators (QIs) suitable for Korean clinical laboratories and investigate the current status of preanalytical phase performance monitoring in Korea using these QIs.Methods: We reviewed previous studies investigating preanalytical QIs including the International Federation of Clinical Chemistry (IFCC) model of QIs, to establish a set of QIs for Korean clinical laboratories.An e-mail survey consisting of this QI set was sent to 90 clinical laboratories.The collected data were analyzed, and performance measures were evaluated according to the quality specifications defined by the IFCC and the sigmascale method.Results: A model consisting of 23 preanalytical phase QIs was established.Approximately 47% (42/90) of clinical laboratories responded to the survey.The average result submission rate for each QI was 56% (standard deviation, 26%).The QIs with the highest and lowest result submission rates were "rejected samples due to hemolysis" (95%) and "recollected sample due to errors caused outside the laboratory" (17%).The QIs with the highest and lowest error rates were "hemolyzed sample detected by hemolytic index" (median, 0.546%; sigma performance level, "good") and "samples not received" (median, 0.001%; sigma performance level, "very good"), respectively.Conclusions: This survey findings on preanalytical phase QIs could serve as a foundation for developing an external quality assessment program for clinical laboratories in Korea.

Journal of Laboratory Medicine and Quality AssuranceVol. 46(3)
Ulsan College (KR), Soonchunhyang University (KR), Asan Medical Center (KR), Samsung Medical Center (KR), Seoul National University Bundang Hospital (KR), University of Ulsan (KR), Sungkyunkwan University (KR)
Openalex Percentile: Top 83%
Meta-analysis and systematic reviews
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.