Investigation of the Durability of a Water Electrolysis Cell with Iridium Fiber Anode Against Voltage Fluctuations Simulating Wind Power

Durability of a water electrolysis cell against the voltage fluctuations is focused on in this study. An accelerated potential fluctuation test was performed for a newly developed MEA with Iridium fiber anode in our lab. In the first 40 sets of the test, no positive effect of the fiber structure was seen, and rather the fast current loss related to gas stagnation was observed. That was assumed to be owing to the coverage on inter-fiber pores by extra Nafion® ionomer. However, in the latter 40 sets, the expansion of the anode layer was confirmed by SEM images, and the rate of gas stagnation was decreased. Furthermore, the recovery of I-V performance after the rest period was sufficiently good, and almost no irreversible degradation was considered. Therefore, the Iridium fiber anode most likely has high durability against the increased internal pressure in the anode layer derived by stagnated gases.

Authors

Publication Details

Journal
ECS Transactions
Published
2024-09-27
DOI
https://doi.org/10.1149/11405.0095ecst
Primary Topic
Hybrid Renewable Energy Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of the Durability of a Water Electrolysis Cell with Iridium Fiber Anode Against Voltage Fluctuations Simulating Wind Power

Akari Hayashi, Kohei Ito, Yasir Arafat Hutapea, S. Nagatomo
ECS Transactions
Hybrid Renewable Energy Systems
article

Investigation of the Durability of a Water Electrolysis Cell with Iridium Fiber Anode Against Voltage Fluctuations Simulating Wind Power

Akari Hayashi, Kohei Ito, Yasir Arafat Hutapea, S. Nagatomo
article en

Abstract

Durability of a water electrolysis cell against the voltage fluctuations is focused on in this study. An accelerated potential fluctuation test was performed for a newly developed MEA with Iridium fiber anode in our lab. In the first 40 sets of the test, no positive effect of the fiber structure was seen, and rather the fast current loss related to gas stagnation was observed. That was assumed to be owing to the coverage on inter-fiber pores by extra Nafion® ionomer. However, in the latter 40 sets, the expansion of the anode layer was confirmed by SEM images, and the rate of gas stagnation was decreased. Furthermore, the recovery of I-V performance after the rest period was sufficiently good, and almost no irreversible degradation was considered. Therefore, the Iridium fiber anode most likely has high durability against the increased internal pressure in the anode layer derived by stagnated gases.

ECS TransactionsVol. 114(5)
Openalex Percentile: Top 85%
Hybrid Renewable Energy Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.