Modeling The Hydrogen Crossover Through Membrane With And Without Catalyst Layers
The hydrogen crossover flux is expressed as a function of the difference in the partial pressure of hydrogen and total pressure difference between the supply and permeate sides of a membrane. The hydrogen crossover rate was measured under several operating conditions by micro gas chromatography. The permeation flux was not influenced by the total pressure difference up to 50 kPa. A bare Nafion membrane and the membrane with catalyst layers were modeled as a stack of bulk and skin layers. Hydrogen permeability of both samples showed identical bulk layer expressed by a power-law equation of the moisture content and an Arrhenius equation of temperature with an activation energy of 22.8 kJ mol– 1 . The measurement of skin layer resistance wasn’t successful since the skin layer resistance was too low to be measured. A skin layer of Nafion with a catalyst layer wasn’t observed due to formation of fused layer.
Authors
- Yulei Ma (ORCID: https://orcid.org/0009-0008-8532-3605)
- Kouichi Nakamichi
- Miho Kageyama (ORCID: https://orcid.org/0000-0003-1853-2235)
- Beste Polat
- Beste Balci Polat
Publication Details
- Journal
- ECS Transactions
- Published
- 2024-09-27
- DOI
- https://doi.org/10.1149/11405.0241ecst
- Primary Topic
- Fuel Cells and Related Materials
- Type
- article
- Field-Weighted Citation Impact
- 0.00