(Invited) Development of Fiber-Optic Hydrogen Sensor Using Platinum-Supported Tungsten Trioxide-Silica Composite Film

A fiber-optic hydrogen gas sensor using a platinum-supported tungsten oxide-silica composite film was fabricated. This sensor utilizes the absorption of the evanescent field interaction in the hydrogen sensitive clad which was composed of WO 3 and SiO 2 , coated on a silica core with sol-gel process. As a first step, transmission spectra of sensing film itself were measured. The transmittance of the sensitive film decreased in the range of wavelengths above about 500 nm after exposure to pure hydrogen, and the change in transmittance at 1300 nm was greater than that at 850 nm. Then, fiber optic sensor device was fabricated, and the amount of propagating light was measured. In the case of using the light source with a wavelength of 1300 nm, the sensitivity with respect to the hydrogen response was nearly twice and the response speed was faster, compared with those at 850 nm.

Authors

Publication Details

Journal
ECS Transactions
Published
2024-09-27
DOI
https://doi.org/10.1149/11407.0013ecst
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

(Invited) Development of Fiber-Optic Hydrogen Sensor Using Platinum-Supported Tungsten Trioxide-Silica Composite Film

Taro Arakawa, Shinji Okazaki, Yoshiaki Nishijima, Erika Ishii
ECS Transactions
Advanced Fiber Optic Sensors
article

(Invited) Development of Fiber-Optic Hydrogen Sensor Using Platinum-Supported Tungsten Trioxide-Silica Composite Film

Taro Arakawa, Shinji Okazaki, Yoshiaki Nishijima, Erika Ishii
article en

Abstract

A fiber-optic hydrogen gas sensor using a platinum-supported tungsten oxide-silica composite film was fabricated. This sensor utilizes the absorption of the evanescent field interaction in the hydrogen sensitive clad which was composed of WO 3 and SiO 2 , coated on a silica core with sol-gel process. As a first step, transmission spectra of sensing film itself were measured. The transmittance of the sensitive film decreased in the range of wavelengths above about 500 nm after exposure to pure hydrogen, and the change in transmittance at 1300 nm was greater than that at 850 nm. Then, fiber optic sensor device was fabricated, and the amount of propagating light was measured. In the case of using the light source with a wavelength of 1300 nm, the sensitivity with respect to the hydrogen response was nearly twice and the response speed was faster, compared with those at 850 nm.

ECS TransactionsVol. 114(7)
Openalex Percentile: Top 86%
Advanced Fiber Optic Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.