Electrochemical Impedance Spectra Measurements and Analysis of Polymer Electrolyte Membrane Electrolysis on Short Stack

Transferring Electrochemical Impedance spectroscopy from fundamental research towards close to application systems allows direct insights into kinetics, transport processes and a state of health indication. Since such stacked systems are optimized for application comprehensive monitoring with reference electrodes is hardly possible. In addition, due to the high power consumption suitable measurement devices are hard to find and the results can only be used to a limited extent. In this work such a test object was set up and tested in different measurement configurations to investigate the reasons for the high noise ratio of the impedance measurement data at more than 200A. It was found that a series circuit consisting of a DC power supply, a high-precision impedance load and the test electrolyser has the least influence on the measurement result of all the methods tested. Finally, the impedance spectra were checked for interpretability using DRT and equivalent circuit fit.

Authors

Publication Details

Journal
ECS Transactions
Published
2024-09-27
DOI
https://doi.org/10.1149/11405.0479ecst
Primary Topic
Fuel Cells and Related Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrochemical Impedance Spectra Measurements and Analysis of Polymer Electrolyte Membrane Electrolysis on Short Stack

Michael Liebert, Joachim Scholta, Ludwig Joerissen
ECS Transactions
Fuel Cells and Related Materials
article

Electrochemical Impedance Spectra Measurements and Analysis of Polymer Electrolyte Membrane Electrolysis on Short Stack

Michael Liebert, Joachim Scholta, Ludwig Joerissen
article en

Abstract

Transferring Electrochemical Impedance spectroscopy from fundamental research towards close to application systems allows direct insights into kinetics, transport processes and a state of health indication. Since such stacked systems are optimized for application comprehensive monitoring with reference electrodes is hardly possible. In addition, due to the high power consumption suitable measurement devices are hard to find and the results can only be used to a limited extent. In this work such a test object was set up and tested in different measurement configurations to investigate the reasons for the high noise ratio of the impedance measurement data at more than 200A. It was found that a series circuit consisting of a DC power supply, a high-precision impedance load and the test electrolyser has the least influence on the measurement result of all the methods tested. Finally, the impedance spectra were checked for interpretability using DRT and equivalent circuit fit.

ECS TransactionsVol. 114(5)
Openalex Percentile: Top 86%
Fuel Cells and Related Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Electrochemical Impedance Spectra Measurements and Analysis of Polymer Electrolyte Membrane Electrolysis on Short Stack — Michael Liebert, Joachim Scholta, et al. · ECS Transactions (2024) | TGRS Research Map | TGRS