Pulmonary Overcirculation Requiring Surgical and Pulmonary Flow Restrictor Device Intervention in Critical Coarctation of the Aorta—A Case Series

The use of prostaglandin infusion to maintain patency of the ductus arteriosus in patients with critical coarctation of the aorta (CoA) to support systemic circulation is the standard of care. However, pulmonary overcirculation resulting from a patent ductus arteriosus in patients with critical CoA is not well described in the literature. We report two cases of critical CoA that required invasive measures to control pulmonary blood flow before surgical repair of the CoA. Both patients had signs of decreased oxygen delivery, hyperlactatemia, and systemic to pulmonary flow via the ductus arteriosus. One patient required surgical pulmonary artery banding and the second patient underwent pulmonary flow restrictor device placement for the control of pulmonary blood flow. A rapid improvement in oxygen delivery and normalization of lactate levels were observed after control of pulmonary overcirculation. Both patients underwent successful surgical repair of the coarctation A and were discharged home.

Authors

Publication Details

Journal
World Journal for Pediatric and Congenital Heart Surgery
Published
2024-09-27
DOI
https://doi.org/10.1177/21501351241278576
Primary Topic
Congenital Heart Disease Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pulmonary Overcirculation Requiring Surgical and Pulmonary Flow Restrictor Device Intervention in Critical Coarctation of the Aorta—A Case Series

Christine Cha, Michael Argilla, Sunil Saharan, T. K. Susheel Kumar et al.
World Journal for Pediatric and Congenital Heart Surgery
Congenital Heart Disease Studies
article

Pulmonary Overcirculation Requiring Surgical and Pulmonary Flow Restrictor Device Intervention in Critical Coarctation of the Aorta—A Case Series

Christine Cha, Michael Argilla, Sunil Saharan, T. K. Susheel Kumar, Shivanand Medar, Sujata Chakravarti, Ralph S. Mosca, Esther Yewoon Choi
article en

Abstract

The use of prostaglandin infusion to maintain patency of the ductus arteriosus in patients with critical coarctation of the aorta (CoA) to support systemic circulation is the standard of care. However, pulmonary overcirculation resulting from a patent ductus arteriosus in patients with critical CoA is not well described in the literature. We report two cases of critical CoA that required invasive measures to control pulmonary blood flow before surgical repair of the CoA. Both patients had signs of decreased oxygen delivery, hyperlactatemia, and systemic to pulmonary flow via the ductus arteriosus. One patient required surgical pulmonary artery banding and the second patient underwent pulmonary flow restrictor device placement for the control of pulmonary blood flow. A rapid improvement in oxygen delivery and normalization of lactate levels were observed after control of pulmonary overcirculation. Both patients underwent successful surgical repair of the coarctation A and were discharged home.

World Journal for Pediatric and Congenital Heart SurgeryVol. 16(1)
Good health and well-being
Openalex Percentile: Top 75%
Congenital Heart Disease Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.