Fast separation and determination of 55Fe and 63Ni using chelating resin Chelex 100 for activated parts of nuclear reactors and nuclear forensics

Abstract In this study, a method for selective separation of 63 Ni and 55 Fe with simultaneous wash-out of 60 Co was developed. Purification of 63 Ni and 55 Fe was carried out using a chelating ion-exchange resin Chelex 100. The elaborated procedure was applied for aqueous and stainless steel matrices. Average recoveries were around 80% for both isotopes, confirmed by ICP-MS and LSC measurements. 60 Co, interfering with the isotopes spectra in the same energy range, was washed-out from the system prior to 63 Ni and 55 Fe separation. The most important advantages over existing methods are short separation time (c.a. 8 h), application of a single chromatographic column and overall simplicity.

Authors

Institutions

Publication Details

Journal
Journal of Radioanalytical and Nuclear Chemistry
Published
2024-09-27
DOI
https://doi.org/10.1007/s10967-024-09787-x
Citations
1
Primary Topic
Radioactive contamination and transfer
Type
article
Field-Weighted Citation Impact
0.28

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fast separation and determination of 55Fe and 63Ni using chelating resin Chelex 100 for activated parts of nuclear reactors and nuclear forensics

Ewelina Chajduk, Zbigniew Samczyński, Marek Trojanowicz, Ewa Topyła
1 citations
Journal of Radioanalytical and Nuclear Chemistry
Radioactive contamination and transfer
0.28
article

Fast separation and determination of 55Fe and 63Ni using chelating resin Chelex 100 for activated parts of nuclear reactors and nuclear forensics

Ewelina Chajduk, Zbigniew Samczyński, Marek Trojanowicz, Ewa Topyła
article en
1 citations

Abstract

Abstract In this study, a method for selective separation of 63 Ni and 55 Fe with simultaneous wash-out of 60 Co was developed. Purification of 63 Ni and 55 Fe was carried out using a chelating ion-exchange resin Chelex 100. The elaborated procedure was applied for aqueous and stainless steel matrices. Average recoveries were around 80% for both isotopes, confirmed by ICP-MS and LSC measurements. 60 Co, interfering with the isotopes spectra in the same energy range, was washed-out from the system prior to 63 Ni and 55 Fe separation. The most important advantages over existing methods are short separation time (c.a. 8 h), application of a single chromatographic column and overall simplicity.

Journal of Radioanalytical and Nuclear ChemistryVol. 333(12)
Instytut Chemii i Techniki Jądrowej (PL)
International Atomic Energy Agency
Openalex Percentile: Top 42%
Radioactive contamination and transfer
0.28
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.