Crosslinked All-Femtosecond Laser-Cut Corneal Allogenic Intracorneal Ring Segments (AFXL CAIRSs): Pilot Ex Vivo Study and Report of First Two Cases Performed in Italy

<b>Objectives:</b> This pilot ex vivo study and first clinical experience in Italy evaluate the impact of using pre-implantation crosslinking on all-femtosecond laser-cut corneal allogenic intracorneal ring segments (AFXL CAIRSs). <b>Methods:</b> Six human donor eye-bank corneas were used for this preclinical ex vivo human study. Three donor (D) corneas were used for AFXL CAIRSs. First, they were prepared with an IntraLase™ femtosecond laser (Johnson & Johnson, New Brunswick, NJ, USA). The allogenic tissue rings were crosslinked before implantation with Riboflavin-UV-A accelerated crosslinking protocol (ACXL) with a 0.1% HPMC Riboflavin isotonic solution (Vibex Rapid, Glaukos-Avedro, Burlington, MA, USA) and a new KXL UV-A emitter (Glaukos-Avedro, USA). Three corneas were used as recipients (Rs) of the AFXL CAIRSs. After completing the ex vivo phase, IRB approval and signing a specific informed consent, the first two Italian patients were treated. A single ACXL CAIRS was implanted in a 51-year-old male with 53.53 D K steep, 363 μm minimum corneal thickness (MCT) and a double ACXL CAIRS was implanted in a 46-year-old male patient with 58.30 D K steep, 443 μm MCT. The longest follow-up was at three months. <b>Results:</b> Crosslinking of the segments enhanced tissue stiffness and grip, facilitating manipulation and CAIRS insertion into the recipient tunnels, and the yellowish color of the crosslinked segments improved visibility. The segment's thickness and volume remained unaltered during the follow-up. Both patients improved UDVA and BSCVA. K steep and High-Order Aberrations (HOAs) were reduced and MCT increased. <b>Conclusions:</b> Pre-implantation ACXL facilitated CAIRS insertion preserving dimensions and volume during the follow-up, rendering this important step a promising candidate in method standardization. Functional data and MCT improved significantly without adverse events.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2024-09-27
DOI
https://doi.org/10.3390/jcm13195771
Citations
4
Primary Topic
Corneal surgery and disorders
Type
article
Field-Weighted Citation Impact
1.62
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Crosslinked All-Femtosecond Laser-Cut Corneal Allogenic Intracorneal Ring Segments (AFXL CAIRSs): Pilot Ex Vivo Study and Report of First Two Cases Performed in Italy

Farhad Hafezi, Shady T. Awwad, Emílio A. Torres-Netto, Marco Zagari et al.
4 citations
Journal of Clinical Medicine
Corneal surgery and disorders
1.62
article

Crosslinked All-Femtosecond Laser-Cut Corneal Allogenic Intracorneal Ring Segments (AFXL CAIRSs): Pilot Ex Vivo Study and Report of First Two Cases Performed in Italy

Farhad Hafezi, Shady T. Awwad, Emílio A. Torres-Netto, Marco Zagari, Cosimo Giuseppe Mazzotta, Diego Ponzin, Giulia Bona, Soosan Jacob
article en
4 citations

Abstract

<b>Objectives:</b> This pilot ex vivo study and first clinical experience in Italy evaluate the impact of using pre-implantation crosslinking on all-femtosecond laser-cut corneal allogenic intracorneal ring segments (AFXL CAIRSs). <b>Methods:</b> Six human donor eye-bank corneas were used for this preclinical ex vivo human study. Three donor (D) corneas were used for AFXL CAIRSs. First, they were prepared with an IntraLase™ femtosecond laser (Johnson & Johnson, New Brunswick, NJ, USA). The allogenic tissue rings were crosslinked before implantation with Riboflavin-UV-A accelerated crosslinking protocol (ACXL) with a 0.1% HPMC Riboflavin isotonic solution (Vibex Rapid, Glaukos-Avedro, Burlington, MA, USA) and a new KXL UV-A emitter (Glaukos-Avedro, USA). Three corneas were used as recipients (Rs) of the AFXL CAIRSs. After completing the ex vivo phase, IRB approval and signing a specific informed consent, the first two Italian patients were treated. A single ACXL CAIRS was implanted in a 51-year-old male with 53.53 D K steep, 363 μm minimum corneal thickness (MCT) and a double ACXL CAIRS was implanted in a 46-year-old male patient with 58.30 D K steep, 443 μm MCT. The longest follow-up was at three months. <b>Results:</b> Crosslinking of the segments enhanced tissue stiffness and grip, facilitating manipulation and CAIRS insertion into the recipient tunnels, and the yellowish color of the crosslinked segments improved visibility. The segment's thickness and volume remained unaltered during the follow-up. Both patients improved UDVA and BSCVA. K steep and High-Order Aberrations (HOAs) were reduced and MCT increased. <b>Conclusions:</b> Pre-implantation ACXL facilitated CAIRS insertion preserving dimensions and volume during the follow-up, rendering this important step a promising candidate in method standardization. Functional data and MCT improved significantly without adverse events.

Journal of Clinical MedicineVol. 13(19)
University of Siena (IT), University of Zurich (CH), American University of Beirut Medical Center (LB), Veneto Eye Bank Foundation (IT), ELZA Institute (CH), Dr. Agarwal's Eye Hospital (IN)
Openalex Percentile: Top 16%
Corneal surgery and disorders
1.62
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.