A Novel Approach to Enhancing the Determination of Primary Indicators in Non-Idealised Absorption Chillers

The accurate optimisation of absorption chillers is often impeded by idealised models that overlook system interactions and machine complexities. This study introduces a validated mathematical description for predicting the primary indicators of non-idealised absorption chillers, accounting for factors such as the electrical work of the Solution Circulation Pump, entropy changes within the refrigerant cycle, and exergy losses. Validation against 13 years of data (2008–2021) from the University of Debrecen’s absorption chiller indicated close agreement, with deviations within acceptable limits. The use of a solution heat exchanger shifted cooling indicators towards their minima. Sensitivity analyses indicated that a 2.5% reduction in condenser temperature increased COP by 41.3% and Cooling Exergetic Efficiency by 15.5%, while a 2.5% reduction in the Heat Fraction Factor improved both by 34%. Adjusting absorber temperature and Heat Fraction Factor down by 2.5%, alongside a 2.5% rise in generator temperature, resulted in a 100.8% increase in COP and a 52.8% boost in Cooling Exergetic Efficiency. These insights provide a solid foundation for future optimisation strategies in real-life absorption chiller systems.

Authors

Institutions

Publication Details

Journal
Energies
Published
2024-09-27
DOI
https://doi.org/10.3390/en17194858
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel Approach to Enhancing the Determination of Primary Indicators in Non-Idealised Absorption Chillers

Gábor L. Szabó
Energies
Refrigeration and Air Conditioning Technologies
article

A Novel Approach to Enhancing the Determination of Primary Indicators in Non-Idealised Absorption Chillers

Gábor L. Szabó
article en

Abstract

The accurate optimisation of absorption chillers is often impeded by idealised models that overlook system interactions and machine complexities. This study introduces a validated mathematical description for predicting the primary indicators of non-idealised absorption chillers, accounting for factors such as the electrical work of the Solution Circulation Pump, entropy changes within the refrigerant cycle, and exergy losses. Validation against 13 years of data (2008–2021) from the University of Debrecen’s absorption chiller indicated close agreement, with deviations within acceptable limits. The use of a solution heat exchanger shifted cooling indicators towards their minima. Sensitivity analyses indicated that a 2.5% reduction in condenser temperature increased COP by 41.3% and Cooling Exergetic Efficiency by 15.5%, while a 2.5% reduction in the Heat Fraction Factor improved both by 34%. Adjusting absorber temperature and Heat Fraction Factor down by 2.5%, alongside a 2.5% rise in generator temperature, resulted in a 100.8% increase in COP and a 52.8% boost in Cooling Exergetic Efficiency. These insights provide a solid foundation for future optimisation strategies in real-life absorption chiller systems.

EnergiesVol. 17(19)
University of Debrecen (HU)
Openalex Percentile: Top 84%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Novel Approach to Enhancing the Determination of Primary Indicators in Non-Idealised Absorption Chillers — Gábor L. Szabó · Energies (2024) | TGRS Research Map | TGRS