Effects of PET image reconstruction parameters and tumor-to-background uptake ratio on quantification of PET images from PET/MRI and PET/CT systems

Introduction: PET/CT and PET/MRI are valuable multimodality imaging techniques for visualizing both functional and anatomical information. The most used PET reconstruction algorithm is Ordered Subset Expectation Maximization (OSEM). In OSEM, the image noise increases with increased number of iterations, and the reconstruction needs to be stopped before complete convergence. The Bayesian penalized likelihood (BPL) algorithm, recently introduced, uses a noise penalty factor (β) to achieve full convergence while controlling noise. This study aims to evaluate how reconstruction algorithms and lesion radioactivity levels affect PET image quality and quantitative accuracy across three different PET systems. Materials and Methods: A NEMA phantom was filled with 18F and scanned by one PET/MRI and two PET/CT systems with sphere-to-background concentration ratio (SBR) of 2:1, 4:1, or 10:1. PET images were reconstructed with OSEM or BPL with TOF. The number of iterations and β-values were varied, while the matrix size, number of subsets, and filter size remained constant. Contrast recovery (CR) and background variability (BV) were measured in images. Results: CR increased with increased sphere size and SBR. CR and BV decreased with increased β for the 10mm sphere. Increased number of iterations in OSEM showed increased BV with limited variation in CR. BPL gave higher CR and lower BV values than OSEM. The optimal reconstruction was BPL with β between 150 and 350, where BPL was available, and OSEM with two iterations and 21 subsets for the PET/CT without BPL. Conclusion: BPL outperforms OSEM, and SBR significantly influences tracer uptake quantification in small lesions. Future studies should explore the clinical implications of these findings on diagnosis, staging, prognosis, and treatment follow-up.

Authors

Institutions

Publication Details

Journal
Brazilian Journal of Radiation Sciences
Published
2024-09-27
DOI
https://doi.org/10.15392/2319-0612.2024.2487
Citations
1
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of PET image reconstruction parameters and tumor-to-background uptake ratio on quantification of PET images from PET/MRI and PET/CT systems

Tobias Rosholm, Esmaeil Mehrara, Eva B. Forssell-Aronsson, Amena Ali Hussain
1 citations
Brazilian Journal of Radiation Sciences
Medical Imaging Techniques and Applications
0.40
article

Effects of PET image reconstruction parameters and tumor-to-background uptake ratio on quantification of PET images from PET/MRI and PET/CT systems

Tobias Rosholm, Esmaeil Mehrara, Eva B. Forssell-Aronsson, Amena Ali Hussain
article en
1 citations

Abstract

Introduction: PET/CT and PET/MRI are valuable multimodality imaging techniques for visualizing both functional and anatomical information. The most used PET reconstruction algorithm is Ordered Subset Expectation Maximization (OSEM). In OSEM, the image noise increases with increased number of iterations, and the reconstruction needs to be stopped before complete convergence. The Bayesian penalized likelihood (BPL) algorithm, recently introduced, uses a noise penalty factor (β) to achieve full convergence while controlling noise. This study aims to evaluate how reconstruction algorithms and lesion radioactivity levels affect PET image quality and quantitative accuracy across three different PET systems. Materials and Methods: A NEMA phantom was filled with 18F and scanned by one PET/MRI and two PET/CT systems with sphere-to-background concentration ratio (SBR) of 2:1, 4:1, or 10:1. PET images were reconstructed with OSEM or BPL with TOF. The number of iterations and β-values were varied, while the matrix size, number of subsets, and filter size remained constant. Contrast recovery (CR) and background variability (BV) were measured in images. Results: CR increased with increased sphere size and SBR. CR and BV decreased with increased β for the 10mm sphere. Increased number of iterations in OSEM showed increased BV with limited variation in CR. BPL gave higher CR and lower BV values than OSEM. The optimal reconstruction was BPL with β between 150 and 350, where BPL was available, and OSEM with two iterations and 21 subsets for the PET/CT without BPL. Conclusion: BPL outperforms OSEM, and SBR significantly influences tracer uptake quantification in small lesions. Future studies should explore the clinical implications of these findings on diagnosis, staging, prognosis, and treatment follow-up.

Brazilian Journal of Radiation SciencesVol. 12(3)
Sahlgrenska University Hospital (SE), University of Gothenburg (SE)
Openalex Percentile: Top 34%
Medical Imaging Techniques and Applications
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.