Experimental study on bioaerosols behavior and purification measures in a subway compartment

Bioaerosols in public transportation systems raise critical environmental concerns, seriously threatening passenger health and safety. In this study, we investigate the spread characteristics of bioaerosols in a standard type-B subway compartment using both air sampling and sediment sampling methods. Additionally, without compromising indoor passenger comfort, two self-designed air purification devices, based on intense field dielectric (IFD) and dielectric barrier discharge (DBD) technologies, respectively, are successfully applied for the improvement of the subway air quality. The results show that bioaerosols can propagate rapidly throughout the entire compartment in 5 min via airborne transmission. Under the effect of the symmetric air ducts and compartment structure, the difference in bioaerosol concentration in the air is less than 10% between both ends of the compartment. Concurrent substantial bioaerosol deposition on the ground, seats, and windows underscores the risk of contact transmission. Furthermore, the real-time purification rates of the two devices integrated into the air conditioning system reach 59.40% and 44.98%, respectively. With their demonstrated high efficiency in purifying bioaerosols and modular design featuring low energy consumption, easy cleaning, and reusability, these devices stand out as viable long-term solutions for large traffic vehicles. These research findings provide practical equipment recommendations and installation strategies for optimizing indoor air quality in subways and are applicable to other similar transportation systems.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-09-27
DOI
https://doi.org/10.1038/s41598-024-73933-4
Citations
5
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
2.09

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental study on bioaerosols behavior and purification measures in a subway compartment

Zhen Huang, Zhiqiang Fan, Renze Xu, Fan Wu et al.
5 citations
Scientific Reports
Infection Control and Ventilation
2.09
article

Experimental study on bioaerosols behavior and purification measures in a subway compartment

Zhen Huang, Zhiqiang Fan, Renze Xu, Fan Wu, Lian Shen, Jianci Yu
article en
5 citations

Abstract

Bioaerosols in public transportation systems raise critical environmental concerns, seriously threatening passenger health and safety. In this study, we investigate the spread characteristics of bioaerosols in a standard type-B subway compartment using both air sampling and sediment sampling methods. Additionally, without compromising indoor passenger comfort, two self-designed air purification devices, based on intense field dielectric (IFD) and dielectric barrier discharge (DBD) technologies, respectively, are successfully applied for the improvement of the subway air quality. The results show that bioaerosols can propagate rapidly throughout the entire compartment in 5 min via airborne transmission. Under the effect of the symmetric air ducts and compartment structure, the difference in bioaerosol concentration in the air is less than 10% between both ends of the compartment. Concurrent substantial bioaerosol deposition on the ground, seats, and windows underscores the risk of contact transmission. Furthermore, the real-time purification rates of the two devices integrated into the air conditioning system reach 59.40% and 44.98%, respectively. With their demonstrated high efficiency in purifying bioaerosols and modular design featuring low energy consumption, easy cleaning, and reusability, these devices stand out as viable long-term solutions for large traffic vehicles. These research findings provide practical equipment recommendations and installation strategies for optimizing indoor air quality in subways and are applicable to other similar transportation systems.

Scientific ReportsVol. 14(1)
Central South University (CN), Hunan University (CN), Changsha University (CN), Hunan Institute of Microbiology (CN), Ministry of Education and Child Care (CA)
National Natural Science Foundation of China, Training Program for Excellent Young Innovators of Changsha
Openalex Percentile: Top 12%
Infection Control and Ventilation
2.09
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.