High-Throughput Drug Stability Assessment via Biomimetic Metalloporphyrin-Catalyzed Reactions Using Laser-Assisted Rapid Evaporative Ionization Mass Spectrometry (LA-REIMS)

<b>Background:</b> Building extensive drug candidate libraries as early in the development pipeline as possible, with high-throughput in vitro absorption, distribution, metabolism, and excretion (ADME) profiling, is crucial for the selection of lead compounds to guide subsequent research and production phases. Traditionally, the analysis of metabolic stability assays heavily relies on high-throughput LC-MS/MS (liquid chromatography tandem mass spectrometry) techniques to meet with the lead profiling demands. Laser-assisted rapid evaporative ionization mass spectrometry (LA-REIMS) is a quick and efficient technique for characterizing complex biological samples without laborious sample preparation. <b>Objective:</b> In this study, using an automated LA-REIMS well plate reader, achieving an 8 s per sample measurement time, the oxidative metabolic stability of active drug agents was assessed using biomimetic metalloporphyrin-based oxidative model reactions. <b>Results:</b> The results obtained using the novel LA-REIMS-based protocol were compared to and corroborated by those obtained using conventional HPLC-UV-MS (high performance liquid chromatography with ultra-violet detection coupled with mass spectrometry) measurements. <b>Conclusions:</b> LA-REIMS emerges as a promising technique, demonstrating potential suitability for semi-quantitative high-throughput metabolic stability in an optimized solvent environment.

Authors

Institutions

Publication Details

Journal
Pharmaceutics
Published
2024-09-27
DOI
https://doi.org/10.3390/pharmaceutics16101266
Citations
1
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.24
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-Throughput Drug Stability Assessment via Biomimetic Metalloporphyrin-Catalyzed Reactions Using Laser-Assisted Rapid Evaporative Ionization Mass Spectrometry (LA-REIMS)

György Tibor Balogh, Richard Schäffer, Tamás Karancsi, András Marton et al.
1 citations
Pharmaceutics
Mass Spectrometry Techniques and Applications
0.24
article

High-Throughput Drug Stability Assessment via Biomimetic Metalloporphyrin-Catalyzed Reactions Using Laser-Assisted Rapid Evaporative Ionization Mass Spectrometry (LA-REIMS)

György Tibor Balogh, Richard Schäffer, Tamás Karancsi, András Marton, Balázs Decsi, Júlia Balog, Zsombor Mohácsi, Balázs Csillag
article en
1 citations

Abstract

<b>Background:</b> Building extensive drug candidate libraries as early in the development pipeline as possible, with high-throughput in vitro absorption, distribution, metabolism, and excretion (ADME) profiling, is crucial for the selection of lead compounds to guide subsequent research and production phases. Traditionally, the analysis of metabolic stability assays heavily relies on high-throughput LC-MS/MS (liquid chromatography tandem mass spectrometry) techniques to meet with the lead profiling demands. Laser-assisted rapid evaporative ionization mass spectrometry (LA-REIMS) is a quick and efficient technique for characterizing complex biological samples without laborious sample preparation. <b>Objective:</b> In this study, using an automated LA-REIMS well plate reader, achieving an 8 s per sample measurement time, the oxidative metabolic stability of active drug agents was assessed using biomimetic metalloporphyrin-based oxidative model reactions. <b>Results:</b> The results obtained using the novel LA-REIMS-based protocol were compared to and corroborated by those obtained using conventional HPLC-UV-MS (high performance liquid chromatography with ultra-violet detection coupled with mass spectrometry) measurements. <b>Conclusions:</b> LA-REIMS emerges as a promising technique, demonstrating potential suitability for semi-quantitative high-throughput metabolic stability in an optimized solvent environment.

PharmaceuticsVol. 16(10)
Semmelweis University (HU), Waters (United States) (US), Budapest University of Technology and Economics (HU), Water Resources Research Centre (HU)
Openalex Percentile: Top 49%
Mass Spectrometry Techniques and Applications
0.24
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.