Flow through a prosthetic mechanical aortic valve: Numerical model and experimental study

This research presents a numerical model dedicated for virtual patient diagnostics in the field of synthetic valve implantation. The model operates based on computational fluid dynamics solver with implemented rigid body motion solver. Characteristic indicators related to the prosthetic valve were determined to assess the correctness of cardiac system operation after implantation. A novel approach for dynamic time discretization was developed for reliable and time-efficient calculation. The solver efficiency and computational savings due to application of the developed time-discretization scheme is discussed. Numerical results were validated using experimental data acquired from a test rig, including mass flow meter, pressure transducers, and valve holder designed for this purpose. Multivariant analysis of the model constant was performed towards different levels of the valve resistance to motion. The in-house algorithm was prepared to automatically determine the prosthetic valve position from fast camera images.

Authors

Institutions

Publication Details

Journal
Computers & Mathematics with Applications
Published
2024-09-27
DOI
https://doi.org/10.1016/j.camwa.2024.09.010
Citations
1
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Flow through a prosthetic mechanical aortic valve: Numerical model and experimental study

Ryszard A. Białecki, Tomasz Borkowski, Marek Rojczyk, Eduardo Divo et al.
1 citations
Computers & Mathematics with Applications
Cardiac Valve Diseases and Treatments
0.40
article

Flow through a prosthetic mechanical aortic valve: Numerical model and experimental study

Ryszard A. Białecki, Tomasz Borkowski, Marek Rojczyk, Eduardo Divo, Marcin Nowak, E Marciniak
article en
1 citations

Abstract

This research presents a numerical model dedicated for virtual patient diagnostics in the field of synthetic valve implantation. The model operates based on computational fluid dynamics solver with implemented rigid body motion solver. Characteristic indicators related to the prosthetic valve were determined to assess the correctness of cardiac system operation after implantation. A novel approach for dynamic time discretization was developed for reliable and time-efficient calculation. The solver efficiency and computational savings due to application of the developed time-discretization scheme is discussed. Numerical results were validated using experimental data acquired from a test rig, including mass flow meter, pressure transducers, and valve holder designed for this purpose. Multivariant analysis of the model constant was performed towards different levels of the valve resistance to motion. The in-house algorithm was prepared to automatically determine the prosthetic valve position from fast camera images.

Computers & Mathematics with ApplicationsVol. 175
Silesian University of Technology (PL), Gdańsk University of Technology (PL), Gdańsk Medical University (PL), Embry–Riddle Aeronautical University (US)
Openalex Percentile: Top 33%
Cardiac Valve Diseases and Treatments
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Flow through a prosthetic mechanical aortic valve: Numerical model and experimental study — Ryszard A. Białecki, Tomasz Borkowski, et al. · Computers & Mathematics with Applications (2024) | TGRS Research Map | TGRS