Step Width Estimation in Individuals With and Without Neurodegenerative Disease via a Novel Data-Augmentation Deep Learning Model and Minimal Wearable Inertial Sensors

Step width is vital for gait stability, postural balance control, and fall risk reduction. However, estimating step width typically requires either fixed cameras or a full kinematic body suit of wearable inertial measurement units (IMUs), both of which are often too expensive and time-consuming for clinical application. We thus propose a novel data-augmented deep learning model for estimating step width in individuals with and without neurodegenerative disease using a minimal set of wearable IMUs. Twelve patients with neurodegenerative, clinically diagnosed Spinocerebellar ataxia type 3 (SCA3) performed over ground walking trials, and seventeen healthy individuals performed treadmill walking trials at various speeds and gait modifications while wearing IMUs on each shank and the pelvis. Results demonstrated step width mean absolute errors of 3.3 0.7 cm and 2.9 0.5 cm for the neurodegenerative and healthy groups, respectively, which were below the minimal clinically important difference of 6.0 cm. Step width variability mean absolute errors were 1.5 cm and 0.8 cm for neurodegenerative and healthy groups, respectively. Data augmentation significantly improved accuracy performance in the neurodegenerative group, likely because they exhibited larger variations in walking kinematics as compared with healthy subjects. These results could enable clinically meaningful and accurate portable step width monitoring for individuals with and without neurodegenerative disease, potentially enhancing rehabilitative training, assessment, and dynamic balance control in clinical and real-life settings.

Authors

Institutions

Publication Details

Journal
IEEE Journal of Biomedical and Health Informatics
Published
2024-09-27
DOI
https://doi.org/10.1109/jbhi.2024.3470310
Citations
5
Primary Topic
Balance, Gait, and Falls Prevention
Type
article
Field-Weighted Citation Impact
5.72

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Step Width Estimation in Individuals With and Without Neurodegenerative Disease via a Novel Data-Augmentation Deep Learning Model and Minimal Wearable Inertial Sensors

Marina Brozgol, Jeffrey M. Hausdorff, Tian Tan, Penina Ponger et al.
5 citations
IEEE Journal of Biomedical and Health Informatics
Balance, Gait, and Falls Prevention
5.72
article

Step Width Estimation in Individuals With and Without Neurodegenerative Disease via a Novel Data-Augmentation Deep Learning Model and Minimal Wearable Inertial Sensors

Marina Brozgol, Jeffrey M. Hausdorff, Tian Tan, Penina Ponger, Eran Gazit, Peter B. Shull, Hong Wang, Zakir Ullah
article en
5 citations

Abstract

Step width is vital for gait stability, postural balance control, and fall risk reduction. However, estimating step width typically requires either fixed cameras or a full kinematic body suit of wearable inertial measurement units (IMUs), both of which are often too expensive and time-consuming for clinical application. We thus propose a novel data-augmented deep learning model for estimating step width in individuals with and without neurodegenerative disease using a minimal set of wearable IMUs. Twelve patients with neurodegenerative, clinically diagnosed Spinocerebellar ataxia type 3 (SCA3) performed over ground walking trials, and seventeen healthy individuals performed treadmill walking trials at various speeds and gait modifications while wearing IMUs on each shank and the pelvis. Results demonstrated step width mean absolute errors of 3.3 0.7 cm and 2.9 0.5 cm for the neurodegenerative and healthy groups, respectively, which were below the minimal clinically important difference of 6.0 cm. Step width variability mean absolute errors were 1.5 cm and 0.8 cm for neurodegenerative and healthy groups, respectively. Data augmentation significantly improved accuracy performance in the neurodegenerative group, likely because they exhibited larger variations in walking kinematics as compared with healthy subjects. These results could enable clinically meaningful and accurate portable step width monitoring for individuals with and without neurodegenerative disease, potentially enhancing rehabilitative training, assessment, and dynamic balance control in clinical and real-life settings.

IEEE Journal of Biomedical and Health InformaticsVol. 29(1)
Shanghai Jiao Tong University (CN), Tel Aviv Sourasky Medical Center (IL), Stanford University (US)
National Natural Science Foundation of China
Openalex Percentile: Top 4%
Balance, Gait, and Falls Prevention
5.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.