IMU-Assisted Target-Free Extrinsic Calibration of Heterogeneous Lidars Based on Continuous-Time Optimization

Data fusion of heterogeneous LiDAR systems has gained significant attention due to its potential for providing wide-range sensing and high-density measurements for robots. However, existing LiDAR calibration methods primarily focus on homogeneous LiDAR systems and yield suboptimal outcomes when applied to heterogeneous setups. To this end, this paper proposes an IMU-Assisted Heterogeneous LiDAR extrinsics Calibration method, namely IA-HeLiC, which is a target-free method based on continuous-time optimization. Specifically, IA-HeLiC utilizes two types of errors, namely geometric constraint error and motion constraint error, and minimizes them within a B-spline-based continuous-time framework to achieve accurate extrinsic calibration. Using a parameter loopback mechanism, this optimization process is performed iteratively to further improve calibration accuracy. IA-HeLiC’s performance is corroborated through experiments using a ground-truth-known handheld device, by which multiple data sequences were collected in diverse real-world scenes. To make our results reproducible, the source code and the collected dataset have been released at https://cslinzhang.github.io/IA-HeLiC.

Authors

Institutions

Publication Details

Published
2024-09-27
DOI
https://doi.org/10.1109/icip51287.2024.10648154
Primary Topic
Advanced Optical Sensing Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

IMU-Assisted Target-Free Extrinsic Calibration of Heterogeneous Lidars Based on Continuous-Time Optimization

Zehao Yan, Zhong Wang, Lin Zhang, Shenjie Zhao
Advanced Optical Sensing Technologies
article

IMU-Assisted Target-Free Extrinsic Calibration of Heterogeneous Lidars Based on Continuous-Time Optimization

Zehao Yan, Zhong Wang, Lin Zhang, Shenjie Zhao
article en

Abstract

Data fusion of heterogeneous LiDAR systems has gained significant attention due to its potential for providing wide-range sensing and high-density measurements for robots. However, existing LiDAR calibration methods primarily focus on homogeneous LiDAR systems and yield suboptimal outcomes when applied to heterogeneous setups. To this end, this paper proposes an IMU-Assisted Heterogeneous LiDAR extrinsics Calibration method, namely IA-HeLiC, which is a target-free method based on continuous-time optimization. Specifically, IA-HeLiC utilizes two types of errors, namely geometric constraint error and motion constraint error, and minimizes them within a B-spline-based continuous-time framework to achieve accurate extrinsic calibration. Using a parameter loopback mechanism, this optimization process is performed iteratively to further improve calibration accuracy. IA-HeLiC’s performance is corroborated through experiments using a ground-truth-known handheld device, by which multiple data sequences were collected in diverse real-world scenes. To make our results reproducible, the source code and the collected dataset have been released at https://cslinzhang.github.io/IA-HeLiC.

Tongji University (CN), Shanghai Jiao Tong University (CN)
National Natural Science Foundation of China, Fundamental Research Funds for the Central Universities
Openalex Percentile: Top 86%
Advanced Optical Sensing Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

IMU-Assisted Target-Free Extrinsic Calibration of Heterogeneous Lidars Based on Continuous-Time Optimization — Zehao Yan, Zhong Wang, et al. · (2024) | TGRS Research Map | TGRS