Seismic performance study of a 220kV transformer under seismic actions in different directions

The large transformer is a critical component of substations and has historically suffered significant damage during earthquakes. This study develops an enhanced finite element model of a 220kV transformer to accurately assess its seismic performance. The study examines the seismic response characteristics and equipment resilience by utilizing four sets of typical seismic wave records. This enables the identification of critical failure locations and responses. The study results indicate that the high-voltage bushing, a critical component of the 220kV transformer, is susceptible to equipment failure due to excessive stress at the root and displacement at the top. Under the seismic action of a 9-degree design-level earthquake, the seismic resistance of the transformer in the X direction is insufficient.

Authors

Institutions

Publication Details

Published
2024-09-27
DOI
https://doi.org/10.1117/12.3037683
Primary Topic
Drilling and Well Engineering
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Seismic performance study of a 220kV transformer under seismic actions in different directions

Dexu Zou, Zhou Fangrong, Qingyun Min, Weiju Dai et al.
Drilling and Well Engineering
article

Seismic performance study of a 220kV transformer under seismic actions in different directions

Dexu Zou, Zhou Fangrong, Qingyun Min, Weiju Dai, Zhihu Hong, Dengjie Zhu, Qiyuan Cui, Can Sun, Xiangpeng Tan, Longchang Zhu
article en

Abstract

The large transformer is a critical component of substations and has historically suffered significant damage during earthquakes. This study develops an enhanced finite element model of a 220kV transformer to accurately assess its seismic performance. The study examines the seismic response characteristics and equipment resilience by utilizing four sets of typical seismic wave records. This enables the identification of critical failure locations and responses. The study results indicate that the high-voltage bushing, a critical component of the 220kV transformer, is susceptible to equipment failure due to excessive stress at the root and displacement at the top. Under the seismic action of a 9-degree design-level earthquake, the seismic resistance of the transformer in the X direction is insufficient.

China Southern Power Grid (China) (CN)
Climate action
Openalex Percentile: Top 79%
Drilling and Well Engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.