Analysis and research on a protection dialing code skip of feeder terminal unit

In order to improve the power supply reliability of the distribution network and build a digital distribution network, power supply companies in most provinces have carried out the construction of distribution automation system. The feeder terminal unit (FTU) has relay protection function. The incorrect operation of breaker sometimes caused by the wrong configuration of FTU parameters. The paper analyzes a distribution network failure involving the incorrect operation of the FTU relay protection. Firstly, the process of distribution network fault is introduced. Then, the paper analyzes the results of the accuracy test, protection value analysis, SOE analysis, and device disassembly analysis of the FTU. Finally, the paper provides a detailed analysis of the fault result and proposes rectification suggestions. Through the fault analysis, the paper aims to optimize the parameter configuration of FTU relay protection and improves the reliability of distribution network.

Authors

Institutions

Publication Details

Published
2024-09-27
DOI
https://doi.org/10.1117/12.3037949
Primary Topic
Power Systems and Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis and research on a protection dialing code skip of feeder terminal unit

Yajuan Wang, Xuan Li, Weichen Liang, Xiaoyou Huang et al.
Power Systems and Technologies
article

Analysis and research on a protection dialing code skip of feeder terminal unit

Yajuan Wang, Xuan Li, Weichen Liang, Xiaoyou Huang, Jie Li
article en

Abstract

In order to improve the power supply reliability of the distribution network and build a digital distribution network, power supply companies in most provinces have carried out the construction of distribution automation system. The feeder terminal unit (FTU) has relay protection function. The incorrect operation of breaker sometimes caused by the wrong configuration of FTU parameters. The paper analyzes a distribution network failure involving the incorrect operation of the FTU relay protection. Firstly, the process of distribution network fault is introduced. Then, the paper analyzes the results of the accuracy test, protection value analysis, SOE analysis, and device disassembly analysis of the FTU. Finally, the paper provides a detailed analysis of the fault result and proposes rectification suggestions. Through the fault analysis, the paper aims to optimize the parameter configuration of FTU relay protection and improves the reliability of distribution network.

North China Electric Power University (CN), State Grid Corporation of China (China) (CN), State Nuclear Power Technology Company (China) (CN)
Openalex Percentile: Top 86%
Power Systems and Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.