Matching identical stimuli with the method of adjustment produces counter-intuitive biases

The method of adjustment is a widely used experimental procedure for measuring perceptual biases: subjects adjust a probe stimulus until it perceptually matches the test stimulus. Any resulting difference in feature value between probe and test is thought to reflect their relative perceptual difference (i.e. bias). Here, we challenge this view by empirically testing a fundamental prediction of this perceptual matching interpretation: if test and probe are identical then their match should be unbiased because perceptual distortions cancel out between identical stimuli. We run a psychophysical orientation matching experiment using the method of adjustment. Subjects (N=10) were presented with two orientation-filtered noise stimuli (0.5 deg radius Gaussian window, broadband spatial frequency) equidistant (4.5 deg) on either side of a central fixation mark with response-terminated display. Test and probe stimuli either had low or high noise (orientation) randomly assigned, which resulted in two same-noise and two cross-noise conditions. Test orientations were uniformly sampled from the full range (0 to 180 deg) in steps of 10 deg. Counter-intuitively, we found robust and characteristic repulsive biases away from cardinal orientations in both same-noise conditions. These biases cannot be perceptual because test and probe are identical. In addition, in the cross-noise conditions biases were not inverted when switching test and probe, which replicates a previous result. This is also incompatible with the view that the matches are purely perceptual. Finally, we demonstrate that a holistic matching model where perceptual inference and the matching process both simultaneously operate on all levels of the representational hierarchy, can accurately explains subjects’ matching data from our experiment as well as the data from multiple previous studies. Together, our results demonstrate that biases measured with the method of adjustment are not purely perceptual but rather reflect optimal matching behavior according to a holistic objective.

Authors

Institutions

Publication Details

Journal
Journal of Vision
Published
2024-09-15
DOI
https://doi.org/10.1167/jov.24.10.988
Primary Topic
Technology and Human Factors in Education and Health
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Matching identical stimuli with the method of adjustment produces counter-intuitive biases

Alan A. Stocker, Jiang Mao
Journal of Vision
Technology and Human Factors in Education and Health
article

Matching identical stimuli with the method of adjustment produces counter-intuitive biases

Alan A. Stocker, Jiang Mao
article en

Abstract

The method of adjustment is a widely used experimental procedure for measuring perceptual biases: subjects adjust a probe stimulus until it perceptually matches the test stimulus. Any resulting difference in feature value between probe and test is thought to reflect their relative perceptual difference (i.e. bias). Here, we challenge this view by empirically testing a fundamental prediction of this perceptual matching interpretation: if test and probe are identical then their match should be unbiased because perceptual distortions cancel out between identical stimuli. We run a psychophysical orientation matching experiment using the method of adjustment. Subjects (N=10) were presented with two orientation-filtered noise stimuli (0.5 deg radius Gaussian window, broadband spatial frequency) equidistant (4.5 deg) on either side of a central fixation mark with response-terminated display. Test and probe stimuli either had low or high noise (orientation) randomly assigned, which resulted in two same-noise and two cross-noise conditions. Test orientations were uniformly sampled from the full range (0 to 180 deg) in steps of 10 deg. Counter-intuitively, we found robust and characteristic repulsive biases away from cardinal orientations in both same-noise conditions. These biases cannot be perceptual because test and probe are identical. In addition, in the cross-noise conditions biases were not inverted when switching test and probe, which replicates a previous result. This is also incompatible with the view that the matches are purely perceptual. Finally, we demonstrate that a holistic matching model where perceptual inference and the matching process both simultaneously operate on all levels of the representational hierarchy, can accurately explains subjects’ matching data from our experiment as well as the data from multiple previous studies. Together, our results demonstrate that biases measured with the method of adjustment are not purely perceptual but rather reflect optimal matching behavior according to a holistic objective.

Journal of VisionVol. 24(10)
California University of Pennsylvania (US)
Openalex Percentile: Top 75%
Technology and Human Factors in Education and Health
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.