Elucidating the increased ohmic resistances in zero-gap alkaline water electrolysis

• Assumption of constant Tafel slope in I-V fitting overestimates the ohmic resistance. • In-situ ohmic resistance is up to 27% higher than ex-situ measured value. • Bubbles have a limited, yet significant contribution to ohmic resistance. • Bubbles can adhere to the diaphragm. • 4-terminal configuration is preferable in EIS and IV curve analysis. This study investigates the increased ohmic resistances observed in zero-gap alkaline water electrolyzers, aiming to provide insights that can help enhance electrolyzer efficiency and enable operation at higher current densities. Electrochemical impedance spectroscopy (EIS) has been employed in combination with chronopotentiometry, utilizing a custom-designed flow cell with nickel perforated electrodes and a Zirfon UTP 500 diaphragm. Observed differences in area-ohmic resistance values obtained through I-V fitting and EIS, are ascribed to a non-linear Tafel slope at higher current densities. Ohmic resistance values measured with EIS are up to 27% higher than the ex-situ determined value, a significantly smaller percentage than expected based on previous studies. The presence of bubbles outside and inside the diaphragm is identified as the key factor contributing to this increased resistance. We recommend the use of an improved fitting approach, accounting for non-linear Tafel behavior, and the use of a 4-terminal configuration when performing EIS measurements to minimize cable and contact resistance.

Authors

Institutions

Publication Details

Journal
Electrochimica Acta
Published
2024-09-27
DOI
https://doi.org/10.1016/j.electacta.2024.145161
Citations
26
Primary Topic
Hybrid Renewable Energy Systems
Type
article
Field-Weighted Citation Impact
4.41

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Elucidating the increased ohmic resistances in zero-gap alkaline water electrolysis

Rodrigo Lira Garcia Barros, J. van der Schaaf, Matheus Theodorus de Groot, Mathy H.G. Kelleners et al.
26 citations
Electrochimica Acta
Hybrid Renewable Energy Systems
4.41
article

Elucidating the increased ohmic resistances in zero-gap alkaline water electrolysis

Rodrigo Lira Garcia Barros, J. van der Schaaf, Matheus Theodorus de Groot, Mathy H.G. Kelleners, Thijmen V.N. van der Leegte, Lucas van Bemmel
article en
26 citations

Abstract

• Assumption of constant Tafel slope in I-V fitting overestimates the ohmic resistance. • In-situ ohmic resistance is up to 27% higher than ex-situ measured value. • Bubbles have a limited, yet significant contribution to ohmic resistance. • Bubbles can adhere to the diaphragm. • 4-terminal configuration is preferable in EIS and IV curve analysis. This study investigates the increased ohmic resistances observed in zero-gap alkaline water electrolyzers, aiming to provide insights that can help enhance electrolyzer efficiency and enable operation at higher current densities. Electrochemical impedance spectroscopy (EIS) has been employed in combination with chronopotentiometry, utilizing a custom-designed flow cell with nickel perforated electrodes and a Zirfon UTP 500 diaphragm. Observed differences in area-ohmic resistance values obtained through I-V fitting and EIS, are ascribed to a non-linear Tafel slope at higher current densities. Ohmic resistance values measured with EIS are up to 27% higher than the ex-situ determined value, a significantly smaller percentage than expected based on previous studies. The presence of bubbles outside and inside the diaphragm is identified as the key factor contributing to this increased resistance. We recommend the use of an improved fitting approach, accounting for non-linear Tafel behavior, and the use of a 4-terminal configuration when performing EIS measurements to minimize cable and contact resistance.

Electrochimica ActaVol. 507
Eindhoven University of Technology (NL)
Rijksdienst voor Ondernemend Nederland, Technische Universiteit Eindhoven
Clean water and sanitation
Openalex Percentile: Top 6%
Hybrid Renewable Energy Systems
4.41
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.