Effect of profiled endwall on nozzle guide vane with coolant purge flow

The aerothermal performance of a gas turbine could be improved by applying endwall profiling to the nozzle guide vane. In this study, various thermal performance factors of flat and profiled endwalls with purge coolant flow were investigated using adequate experimental methods. Each experiment was conducted under same exit Reynolds number (300,000) for the flat and profiled endwalls. Because secondary vortices in the nozzle passage were weakened by the endwall profiling, the upstream purge coolant covered the endwall surface wider and further with the profiled endwall. Moreover, the heat transfer coefficient in upstream region could be reduced with the weakened secondary vortex. The experimental results indicated that the area-averaged film cooling effectiveness on the profiled endwall was 67.7 % higher and the area-averaged Sherwood number was 18.3 % lower than those on the flat endwall. Although the downstream region of the profiled endwall exhibited a negative cooling performance, the overall area-averaged net heat flux reduction was 169 % higher than that on the flat endwall. Thus, if an additional cooling system was applied to the downstream region of the passage, the profiled endwall could effectively improve not only the aerodynamic performance but also the cooling performance of the nozzle guide vane. • Profiled endwall shape had advantages on thermal-aero dynamic performance for the gas turbine. • Heat transfer coefficient and film cooling effectiveness were measured by experimental methods. • Net heat flux reduction was compared to estimate the practical heat load on the flat and profiled endwall surface. • From various cooling performance factors, the profiled endwall could effectively reduce the thermal load with purge flow.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2024-09-28
DOI
https://doi.org/10.1016/j.csite.2024.105211
Citations
3
Primary Topic
Turbomachinery Performance and Optimization
Type
article
Field-Weighted Citation Impact
3.90
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of profiled endwall on nozzle guide vane with coolant purge flow

Hyung Hee Cho, Ho Seop Song, Hee Seung Park, Jeong‐Won Lee et al.
3 citations
Case Studies in Thermal Engineering
Turbomachinery Performance and Optimization
3.90
article

Effect of profiled endwall on nozzle guide vane with coolant purge flow

Hyung Hee Cho, Ho Seop Song, Hee Seung Park, Jeong‐Won Lee, Jeongju Kim
article en
3 citations

Abstract

The aerothermal performance of a gas turbine could be improved by applying endwall profiling to the nozzle guide vane. In this study, various thermal performance factors of flat and profiled endwalls with purge coolant flow were investigated using adequate experimental methods. Each experiment was conducted under same exit Reynolds number (300,000) for the flat and profiled endwalls. Because secondary vortices in the nozzle passage were weakened by the endwall profiling, the upstream purge coolant covered the endwall surface wider and further with the profiled endwall. Moreover, the heat transfer coefficient in upstream region could be reduced with the weakened secondary vortex. The experimental results indicated that the area-averaged film cooling effectiveness on the profiled endwall was 67.7 % higher and the area-averaged Sherwood number was 18.3 % lower than those on the flat endwall. Although the downstream region of the profiled endwall exhibited a negative cooling performance, the overall area-averaged net heat flux reduction was 169 % higher than that on the flat endwall. Thus, if an additional cooling system was applied to the downstream region of the passage, the profiled endwall could effectively improve not only the aerodynamic performance but also the cooling performance of the nozzle guide vane. • Profiled endwall shape had advantages on thermal-aero dynamic performance for the gas turbine. • Heat transfer coefficient and film cooling effectiveness were measured by experimental methods. • Net heat flux reduction was compared to estimate the practical heat load on the flat and profiled endwall surface. • From various cooling performance factors, the profiled endwall could effectively reduce the thermal load with purge flow.

Case Studies in Thermal EngineeringVol. 62
Yonsei University (KR), Doosan (South Korea) (KR)
Affordable and clean energy
Openalex Percentile: Top 6%
Turbomachinery Performance and Optimization
3.90
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.