A cyanide-free sample preparation methodology prior to determination of vitamin B12 in infant milk formula using hydrophilic interaction liquid chromatography with fluorescence detection

The analysis of vitamin B<sub>12</sub> in infant formulas typically requires the use of cyanide during sample preparation to convert the unstable vitamers (hydroxocobalamin, methylcobalamin and adenosylcobalamin) to cyanocobalamin, the most stable form of vitamin B<sub>12</sub>. To eliminate the risk to laboratory analysts in handling cyanide, alternative strategies are preferred for the analysis of vitamin B<sub>12</sub>. This research demonstrates the use of cobalamin-derived α-ribazole (a nucleoside moiety of vitamin B<sub>12</sub>) to determine total vitamin B<sub>12</sub> content. Infant formula samples underwent protein denaturation and sugar removal with subsequent acidic hydrolysis and dephosphorylation employed to release α-ribazole, which was isolated by boronate affinity chromatography then analysed by hydrophilic interaction liquid chromatography with fluorescence detection. The method was validated using bovine- and ovine milk-based infant formula samples. The newly developed method was linear over the range of 0.65-6.48 ng mL<sup>-1</sup> with repeatability of 3.78-5.47% relative standard deviation (RSD<sub>r</sub>, n = 10) and an intermediate precision of 3.59-10.0% RSD<sub>iR</sub> (n = 10). The limits of detection and quantitation (LOD and LOQ) were 0.4 and 1.2 μg 100 g<sup>-1</sup> of dry weight, respectively. Accuracy was 68.9-76.4% and 68.7-80.0% at 50 and 150% of typical B<sub>12</sub> concentrations in infant formula, respectively. The validated method was applied to eleven infant formulas and no statistical difference (p = 0.45, α = 0.05) was found when comparing with the results obtained using the AOAC Official Method 2014.02 high performance liquid chromatography with ultraviolet detection that requires the use of cyanide. These results indicate that the newly validated method is not only reliable but also offers a safer alternative for routine vitamin B<sub>12</sub> determination in infant formula while maintaining high accuracy and precision.

Authors

Institutions

Publication Details

Journal
Talanta
Published
2024-09-28
DOI
https://doi.org/10.1016/j.talanta.2024.126970
Citations
2
Primary Topic
Porphyrin Metabolism and Disorders
Type
article
Field-Weighted Citation Impact
0.47

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A cyanide-free sample preparation methodology prior to determination of vitamin B12 in infant milk formula using hydrophilic interaction liquid chromatography with fluorescence detection

Megan N.C. Grainger, Brendon D. Gill, Merilyn Manley‐Harris, Yanan Li
2 citations
Talanta
Porphyrin Metabolism and Disorders
0.47
article

A cyanide-free sample preparation methodology prior to determination of vitamin B12 in infant milk formula using hydrophilic interaction liquid chromatography with fluorescence detection

Megan N.C. Grainger, Brendon D. Gill, Merilyn Manley‐Harris, Yanan Li
article en
2 citations

Abstract

The analysis of vitamin B<sub>12</sub> in infant formulas typically requires the use of cyanide during sample preparation to convert the unstable vitamers (hydroxocobalamin, methylcobalamin and adenosylcobalamin) to cyanocobalamin, the most stable form of vitamin B<sub>12</sub>. To eliminate the risk to laboratory analysts in handling cyanide, alternative strategies are preferred for the analysis of vitamin B<sub>12</sub>. This research demonstrates the use of cobalamin-derived α-ribazole (a nucleoside moiety of vitamin B<sub>12</sub>) to determine total vitamin B<sub>12</sub> content. Infant formula samples underwent protein denaturation and sugar removal with subsequent acidic hydrolysis and dephosphorylation employed to release α-ribazole, which was isolated by boronate affinity chromatography then analysed by hydrophilic interaction liquid chromatography with fluorescence detection. The method was validated using bovine- and ovine milk-based infant formula samples. The newly developed method was linear over the range of 0.65-6.48 ng mL<sup>-1</sup> with repeatability of 3.78-5.47% relative standard deviation (RSD<sub>r</sub>, n = 10) and an intermediate precision of 3.59-10.0% RSD<sub>iR</sub> (n = 10). The limits of detection and quantitation (LOD and LOQ) were 0.4 and 1.2 μg 100 g<sup>-1</sup> of dry weight, respectively. Accuracy was 68.9-76.4% and 68.7-80.0% at 50 and 150% of typical B<sub>12</sub> concentrations in infant formula, respectively. The validated method was applied to eleven infant formulas and no statistical difference (p = 0.45, α = 0.05) was found when comparing with the results obtained using the AOAC Official Method 2014.02 high performance liquid chromatography with ultraviolet detection that requires the use of cyanide. These results indicate that the newly validated method is not only reliable but also offers a safer alternative for routine vitamin B<sub>12</sub> determination in infant formula while maintaining high accuracy and precision.

TalantaVol. 282
Fonterra (New Zealand) (NZ), University of Waikato (NZ)
University of Waikato
Zero hunger
Openalex Percentile: Top 35%
Porphyrin Metabolism and Disorders
0.47
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.