Multirod posterior occipitocervical instrumentation constructs: a biomechanical analysis and initial case series of 10 patients with complex craniocervical pathology

In this proof-of-concept investigation, multiple rods (3- and 4-rods) across the OC junction using a novel occipital plate with single- and dual-headed, modular tulips was safe and effective in stabilizing the OC junction. Accompanying FE analysis demonstrated that multirod constructs decreased primary rod stresses and had lower stresses on occipital and C4 screws compared to 2-rod constructs, while occipital plate stresses were largely similar. Additional clinical studies are needed to confirm these findings and to determine the ultimate utility of multirod constructs across the OC junction.

Authors

Institutions

Publication Details

Journal
The Spine Journal
Published
2024-09-28
DOI
https://doi.org/10.1016/j.spinee.2024.09.022
Citations
3
Primary Topic
Spine and Intervertebral Disc Pathology
Type
article
Field-Weighted Citation Impact
1.27
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multirod posterior occipitocervical instrumentation constructs: a biomechanical analysis and initial case series of 10 patients with complex craniocervical pathology

Alekos A. Theologis, Muzammil Mumtaz, Sudharshan Tripathi, Vijay K. Goel et al.
3 citations
The Spine Journal
Spine and Intervertebral Disc Pathology
1.27
article

Multirod posterior occipitocervical instrumentation constructs: a biomechanical analysis and initial case series of 10 patients with complex craniocervical pathology

Alekos A. Theologis, Muzammil Mumtaz, Sudharshan Tripathi, Vijay K. Goel, Andrew P. Collins, Allan Clark, Alexander W. L. Turner, Shruthi K Varier
article en
3 citations

Abstract

In this proof-of-concept investigation, multiple rods (3- and 4-rods) across the OC junction using a novel occipital plate with single- and dual-headed, modular tulips was safe and effective in stabilizing the OC junction. Accompanying FE analysis demonstrated that multirod constructs decreased primary rod stresses and had lower stresses on occipital and C4 screws compared to 2-rod constructs, while occipital plate stresses were largely similar. Additional clinical studies are needed to confirm these findings and to determine the ultimate utility of multirod constructs across the OC junction.

The Spine JournalVol. 25(2)
University of California, San Francisco (US), University of Washington (US), Alphatec Spine Approach Technologies (United States) (US), Neurological Surgery (US), University of Toledo (US)
Openalex Percentile: Top 20%
Spine and Intervertebral Disc Pathology
1.27
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.