Comparative studies on in-plane shear behavior of masonry wallettes retrofitted with mortar, UHPC, and ECC ferrocement: Shotcrete and prefabricated panels

Masonry walls, prevalent in many historical and contemporary structures, often require retrofitting to meet modern safety and performance standards. Motivated by the need for efficient and reliable retrofitting solutions, this research investigates the potential of various types of ferrocement, reinforced with high-strength steel meshes, to enhance the in-plane shear behavior of brick masonry walls. Through rigorous diagonal compression tests on nine masonry wallettes, the study evaluated the performance of ferrocement overlays in terms of overlay configuration (asymmetric or symmetric), cementitious material type (mortar, ECC, or UHPC), the presence or absence of steel mesh, and construction method (shotcrete or prefabricated panels). The results indicated that UHPC and ECC overlays significantly enhanced post-cracking deformation capacity. Compared to the asymmetric retrofit, the symmetric retrofit led to more uniform deformation in the retrofitted wallette, effectively improving the maximum shear by up to 119 %. While UHPC shotcrete was more effective in improving the shear strength, ECC shotcrete led to the highest rupture shear strain and pseudo-ductility for the retrofitted wallette, reaching 0.83 % and 17.2, respectively. Moreover, although steel mesh inclusion in the ferrocement overlay was crucial in enhancing post-peak ductility, its impact on shear strength of the retrofitted wallettes was minimal. The test results also demonstrated that the developed prefabricated UHPC panels emerged as an effective retrofitting solution to simultaneously improve the strength, deformation capacity, and ductility for masonry wallettes. In addition to the experimental investigation, a new strength model, accounting for various key design variables, was developed, offering reliable shear strength predictions for the retrofitted wallettes.

Authors

Institutions

Publication Details

Journal
Case Studies in Construction Materials
Published
2024-09-27
DOI
https://doi.org/10.1016/j.cscm.2024.e03801
Citations
7
Primary Topic
Innovative concrete reinforcement materials
Type
article
Field-Weighted Citation Impact
1.83
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative studies on in-plane shear behavior of masonry wallettes retrofitted with mortar, UHPC, and ECC ferrocement: Shotcrete and prefabricated panels

Cheng-Hao Yen, Khalid M. Mosalam, Chung‐Chan Hung, You-Xuan Dai
7 citations
Case Studies in Construction Materials
Innovative concrete reinforcement materials
1.83
article

Comparative studies on in-plane shear behavior of masonry wallettes retrofitted with mortar, UHPC, and ECC ferrocement: Shotcrete and prefabricated panels

Cheng-Hao Yen, Khalid M. Mosalam, Chung‐Chan Hung, You-Xuan Dai
article en
7 citations

Abstract

Masonry walls, prevalent in many historical and contemporary structures, often require retrofitting to meet modern safety and performance standards. Motivated by the need for efficient and reliable retrofitting solutions, this research investigates the potential of various types of ferrocement, reinforced with high-strength steel meshes, to enhance the in-plane shear behavior of brick masonry walls. Through rigorous diagonal compression tests on nine masonry wallettes, the study evaluated the performance of ferrocement overlays in terms of overlay configuration (asymmetric or symmetric), cementitious material type (mortar, ECC, or UHPC), the presence or absence of steel mesh, and construction method (shotcrete or prefabricated panels). The results indicated that UHPC and ECC overlays significantly enhanced post-cracking deformation capacity. Compared to the asymmetric retrofit, the symmetric retrofit led to more uniform deformation in the retrofitted wallette, effectively improving the maximum shear by up to 119 %. While UHPC shotcrete was more effective in improving the shear strength, ECC shotcrete led to the highest rupture shear strain and pseudo-ductility for the retrofitted wallette, reaching 0.83 % and 17.2, respectively. Moreover, although steel mesh inclusion in the ferrocement overlay was crucial in enhancing post-peak ductility, its impact on shear strength of the retrofitted wallettes was minimal. The test results also demonstrated that the developed prefabricated UHPC panels emerged as an effective retrofitting solution to simultaneously improve the strength, deformation capacity, and ductility for masonry wallettes. In addition to the experimental investigation, a new strength model, accounting for various key design variables, was developed, offering reliable shear strength predictions for the retrofitted wallettes.

Case Studies in Construction MaterialsVol. 21
Earthquake Engineering Research Institute (US), National Cheng Kung University (TW)
Sustainable cities and communities
Openalex Percentile: Top 16%
Innovative concrete reinforcement materials
1.83
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.