Biomechanical behaviour of tilted abutment after fixed partial denture restoration of CAD/CAM materials
FPDs can be used for restoration within 24° of distal abutment inclination, but protecting the abutments (< 12° especially) and the periodontal tissue (> 12° especially) must be taken seriously. For this purpose, an FPD material with higher strength is recommended.
Authors
- Qianbing Wan (ORCID: https://orcid.org/0000-0002-0028-5881)
- Yichen Xu (ORCID: https://orcid.org/0000-0003-0744-3050)
- Ruyi Li (ORCID: https://orcid.org/0000-0003-0723-1306)
- Zhou Zhu (ORCID: https://orcid.org/0000-0003-3324-483X)
- Xibo Pei (ORCID: https://orcid.org/0000-0003-0386-8262)
- Tong Zhu (ORCID: https://orcid.org/0000-0002-8732-3499)
- Jian Wang (ORCID: https://orcid.org/0000-0001-8812-4398)
- Bin Cheng (ORCID: https://orcid.org/0000-0001-8295-2467)
- Mingxin Qiao
- Jingyi Chen (ORCID: https://orcid.org/0009-0004-6576-1086)
Institutions
- Sichuan University (CN)
Publication Details
- Journal
- BMC Oral Health
- Published
- 2024-09-27
- DOI
- https://doi.org/10.1186/s12903-024-04890-7
- Citations
- 3
- Primary Topic
- Dental materials and restorations
- Type
- article
- Field-Weighted Citation Impact
- 1.21
Funders
- National Key Research and Development Program of China