Lateral resistance performance of hybrid shear wall according to structural insulated panel installation location

In the post and beam structure, the post and beam play a crucial role in directly supporting and transmitting loads, thus making them essential elements in structural design. In cases where the moment resistance performance of the post-beam joint is inadequate, a shear wall and bracing are frequently installed to provide support for horizontal load on the posts and beams. The structural insulated panel (SIP) is increasingly utilized and studied as shear walls alongside light-frame timber construction, owing to its insulation properties as well as its high shear strength. In this study, when using SIP as a shear wall between post and beams, three composite wall structures were considered based on the installation location of the SIPs on the post-beam structure and lateral resistance performance of the hybrid shear wall was evaluated according to the SIP installation location. Depending on the installation location SIPs on the posts and beams, shear strength for I-SIP 150, E-SIP 150, and M-SIP 150 were 23.2, 24.6, and 26.0 kN, respectively. In case of the shear stiffness, I-SIP 150, E-SIP-150, and M-SIP 150 were found to be 4.32, 3.99, and 2.74 kN/mm, respectively.

Authors

Institutions

Publication Details

Journal
BioResources
Published
2024-09-19
DOI
https://doi.org/10.15376/biores.19.4.8411-8426
Primary Topic
Structural Analysis and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Lateral resistance performance of hybrid shear wall according to structural insulated panel installation location

Chul-Ki Kim, Sang Joon Lee, Hyung Woo Lee
BioResources
Structural Analysis and Optimization
article

Lateral resistance performance of hybrid shear wall according to structural insulated panel installation location

Chul-Ki Kim, Sang Joon Lee, Hyung Woo Lee
article en

Abstract

In the post and beam structure, the post and beam play a crucial role in directly supporting and transmitting loads, thus making them essential elements in structural design. In cases where the moment resistance performance of the post-beam joint is inadequate, a shear wall and bracing are frequently installed to provide support for horizontal load on the posts and beams. The structural insulated panel (SIP) is increasingly utilized and studied as shear walls alongside light-frame timber construction, owing to its insulation properties as well as its high shear strength. In this study, when using SIP as a shear wall between post and beams, three composite wall structures were considered based on the installation location of the SIPs on the post-beam structure and lateral resistance performance of the hybrid shear wall was evaluated according to the SIP installation location. Depending on the installation location SIPs on the posts and beams, shear strength for I-SIP 150, E-SIP 150, and M-SIP 150 were 23.2, 24.6, and 26.0 kN, respectively. In case of the shear stiffness, I-SIP 150, E-SIP-150, and M-SIP 150 were found to be 4.32, 3.99, and 2.74 kN/mm, respectively.

BioResourcesVol. 19(4)
Korea Forest Service (KR)
Openalex Percentile: Top 81%
Structural Analysis and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.