Manganese Sulfanyl Porphyrazine–MWCNT Nanohybrid Electrode Material as a Catalyst for H2O2 and Glucose Biosensors

The demetallation reaction of sulfanyl magnesium(II) porphyrazine with N-ethylphthalimide substituents, followed by remetallation with manganese(II) salts, yields the corresponding manganese(III) derivative (Pz3) with high efficiency. This novel manganese(III) sulfanyl porphyrazine was characterized by HPLC and analyzed using UV-Vis, MS, and FT-IR spectroscopy. Electrochemical experiments of Pz3 conducted in dichloromethane revealed electrochemical activity of the new complex due to both manganese and N-ethylphthalimide substituents redox transitions. Subsequently, Pz3 was deposited on multiwalled carbon nanotubes (MWCNTs), and this hybrid material was then applied to glassy carbon electrodes (GC). The resulting hybrid electroactive electrode material, combining manganese(III) porphyrazine with MWCNTs, showed a significant decrease in overpotential of H<sub>2</sub>O<sub>2</sub> oxidation compared to bare GC or GC electrodes modified with only carbon nanotubes (GC/MWCNTs). This improvement, attributed to the electrocatalytic performance of Mn<sup>3+</sup>, enabled linear response and sensitive detection of H<sub>2</sub>O<sub>2</sub> at neutral pH. Furthermore, a glucose oxidase (GOx)-containing biosensing platform was developed by modifying the prepared GC/MWCNT/Pz3 electrode for the electrochemical detection of glucose. The bioelectrode incorporating the newly designed Pz3 exhibited good activity in the presence of glucose, confirming effective electronic communication between the Pz3, GOx and MWCNT surface. The linear range for glucose detection was 0.2-3.7 mM.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2024-09-27
DOI
https://doi.org/10.3390/s24196257
Citations
3
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.63

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Manganese Sulfanyl Porphyrazine–MWCNT Nanohybrid Electrode Material as a Catalyst for H2O2 and Glucose Biosensors

Michał Falkowski, Michał Wiciński, Mina Hassani, Michał Piotr Marszałł et al.
3 citations
Sensors
Electrochemical sensors and biosensors
0.63
article

Manganese Sulfanyl Porphyrazine–MWCNT Nanohybrid Electrode Material as a Catalyst for H2O2 and Glucose Biosensors

Michał Falkowski, Michał Wiciński, Mina Hassani, Michał Piotr Marszałł, Grzegorz Milczarek, Jaroslaw Piskorz, Tomasz Rębiś, Dariusz T. Młynarczyk, Amanda Leda, Nejat Düzgüneş
article en
3 citations

Abstract

The demetallation reaction of sulfanyl magnesium(II) porphyrazine with N-ethylphthalimide substituents, followed by remetallation with manganese(II) salts, yields the corresponding manganese(III) derivative (Pz3) with high efficiency. This novel manganese(III) sulfanyl porphyrazine was characterized by HPLC and analyzed using UV-Vis, MS, and FT-IR spectroscopy. Electrochemical experiments of Pz3 conducted in dichloromethane revealed electrochemical activity of the new complex due to both manganese and N-ethylphthalimide substituents redox transitions. Subsequently, Pz3 was deposited on multiwalled carbon nanotubes (MWCNTs), and this hybrid material was then applied to glassy carbon electrodes (GC). The resulting hybrid electroactive electrode material, combining manganese(III) porphyrazine with MWCNTs, showed a significant decrease in overpotential of H<sub>2</sub>O<sub>2</sub> oxidation compared to bare GC or GC electrodes modified with only carbon nanotubes (GC/MWCNTs). This improvement, attributed to the electrocatalytic performance of Mn<sup>3+</sup>, enabled linear response and sensitive detection of H<sub>2</sub>O<sub>2</sub> at neutral pH. Furthermore, a glucose oxidase (GOx)-containing biosensing platform was developed by modifying the prepared GC/MWCNT/Pz3 electrode for the electrochemical detection of glucose. The bioelectrode incorporating the newly designed Pz3 exhibited good activity in the presence of glucose, confirming effective electronic communication between the Pz3, GOx and MWCNT surface. The linear range for glucose detection was 0.2-3.7 mM.

SensorsVol. 24(19)
University of the Pacific (US), Poznan University of Medical Sciences (PL), Nicolaus Copernicus University (PL), Collegium Medicum in Bydgoszcz (PL), Poznań University of Technology (PL)
Narodowym Centrum Nauki
Openalex Percentile: Top 31%
Electrochemical sensors and biosensors
0.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.