Enhancing radiator cooling capacity: A comparative study of nanofluids and water/EG mixtures

The present study experimentally investigates and compares the performance of a radiator system cooled by a water-ethylene glycol (70:30) based Al<sub>2</sub>O<sub>3</sub>-SiO<sub>2</sub>-TiO<sub>2</sub> nanofluid, with that of a radiator cooled by a water/EG mixture. The equal pumping power criterion of the pump with an equal mass flow rate was used for comparison. Mass flow rate and nanoparticle volume fraction on a radiator cooling system and the radiator's capacity have been studied. Five different nanofluids were prepared with different composition ratios of Al<sub>2</sub>O<sub>3</sub>-SiO<sub>2</sub>-TiO<sub>2</sub> with a total of 0.45 % nanoparticles. The flowrate changed in the range of 0.02-0.032 kg/s. The results showed that the increase in heat transfer is mainly due to the flow velocity and the nanoparticles added in different proportions to the base liquid. The UA value and enhancement ratio of NF1 compared to EG/W is 14-18.5 %, for NF2 it is 14.9-21.8 %, for NF3 it is 15.1-23.4 %, for NF4 it is 15.6-27.5 %, and for NF5 it is 15.9-30 % at 0.02 kg/s and 0.032 kg/s. According to the experimental study results, nanofluids with low concentrations of nanoparticles can enhance the heat transfer rate up to 30 % as a comparison with water/EG.

Authors

Institutions

Publication Details

Journal
Heliyon
Published
2024-09-26
DOI
https://doi.org/10.1016/j.heliyon.2024.e38352
Citations
7
Primary Topic
Nanofluid Flow and Heat Transfer
Type
article
Field-Weighted Citation Impact
1.29
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing radiator cooling capacity: A comparative study of nanofluids and water/EG mixtures

Yasin Karagöz, Tuğba Tetik
7 citations
Heliyon
Nanofluid Flow and Heat Transfer
1.29
article

Enhancing radiator cooling capacity: A comparative study of nanofluids and water/EG mixtures

Yasin Karagöz, Tuğba Tetik
article en
7 citations

Abstract

The present study experimentally investigates and compares the performance of a radiator system cooled by a water-ethylene glycol (70:30) based Al<sub>2</sub>O<sub>3</sub>-SiO<sub>2</sub>-TiO<sub>2</sub> nanofluid, with that of a radiator cooled by a water/EG mixture. The equal pumping power criterion of the pump with an equal mass flow rate was used for comparison. Mass flow rate and nanoparticle volume fraction on a radiator cooling system and the radiator's capacity have been studied. Five different nanofluids were prepared with different composition ratios of Al<sub>2</sub>O<sub>3</sub>-SiO<sub>2</sub>-TiO<sub>2</sub> with a total of 0.45 % nanoparticles. The flowrate changed in the range of 0.02-0.032 kg/s. The results showed that the increase in heat transfer is mainly due to the flow velocity and the nanoparticles added in different proportions to the base liquid. The UA value and enhancement ratio of NF1 compared to EG/W is 14-18.5 %, for NF2 it is 14.9-21.8 %, for NF3 it is 15.1-23.4 %, for NF4 it is 15.6-27.5 %, and for NF5 it is 15.9-30 % at 0.02 kg/s and 0.032 kg/s. According to the experimental study results, nanofluids with low concentrations of nanoparticles can enhance the heat transfer rate up to 30 % as a comparison with water/EG.

HeliyonVol. 10(19)
Istanbul Medeniyet University (TR)
Clean water and sanitation
Openalex Percentile: Top 21%
Nanofluid Flow and Heat Transfer
1.29
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Enhancing radiator cooling capacity: A comparative study of nanofluids and water/EG mixtures — Yasin Karagöz, Tuğba Tetik · Heliyon (2024) | TGRS Research Map | TGRS