Effective Decontamination Methods for Shiga Toxin-producing Escherichia coli on Beef Surfaces for Application in Beef Carcass Hygiene

Effective methods for decontamination of Shiga toxin-producing Escherichia coli (STEC) on beef were evaluated by 48 mL spraying, 100 mL, and 500 mL flushing with ethanol, hydrogen peroxide, peracetic acid, acidified sodium chlorite, and sodium hypochlorite in this study. The flushing with 500 mL of 1,000 ppm peracetic acid was most effective, reducing pathogens by 2.8 log CFU/cm<sup>2</sup>, followed by 1,200 ppm acidified sodium chlorite. The spraying with 1,000 ppm peracetic acid reduced pathogens by 1.6 log CFU/cm<sup>2</sup>. The flushing with 500 mL of 200 and 500 ppm acidified sodium chlorite, and 50, 100, 200, and 500 ppm peracetic acid significantly reduced the STEC population compared with those treated with distilled water (p < 0.05), reducing pathogens by 2.1, 2.4, 1.6, 1.8, 2.1 and 2.4 log CFU/cm<sup>2</sup>, respectively. Additionally, the flushing with 500 mL of 200 and 500 ppm acidified sodium chlorite significantly changed the color of beef samples (p < 0.05), whereas 100-500 ppm peracetic acid did not significantly change the color (p > 0.05). The flushing with 500 mL of 200 and 500 ppm acidified sodium chlorite and 200 and 500 ppm peracetic acid significantly changed the odor of beef samples compared with those treated with distilled water (p < 0.05). There was no difference in the reduction of STEC population between peracetic acid treatment at 25 °C and 55 °C, with or without washing with sterilized distilled water after decontamination. Washing with distilled water after flushing with peracetic acid tended to reduce the odor of the samples. These results suggest that treatment with 100, 200, and 500 ppm peracetic acid, followed by washing with distilled water, might reduce the STEC population without retaining the odor of the sanitizer.

Authors

Institutions

Publication Details

Journal
Journal of Food Protection
Published
2024-09-26
DOI
https://doi.org/10.1016/j.jfp.2024.100366
Citations
1
Primary Topic
Escherichia coli research studies
Type
article
Field-Weighted Citation Impact
0.62
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effective Decontamination Methods for Shiga Toxin-producing Escherichia coli on Beef Surfaces for Application in Beef Carcass Hygiene

Akiko Tomaru, Shouhei Hirose, Yukiko Hara‐Kudo, Hiroshi Akiyama
1 citations
Journal of Food Protection
Escherichia coli research studies
0.62
article

Effective Decontamination Methods for Shiga Toxin-producing Escherichia coli on Beef Surfaces for Application in Beef Carcass Hygiene

Akiko Tomaru, Shouhei Hirose, Yukiko Hara‐Kudo, Hiroshi Akiyama
article en
1 citations

Abstract

Effective methods for decontamination of Shiga toxin-producing Escherichia coli (STEC) on beef were evaluated by 48 mL spraying, 100 mL, and 500 mL flushing with ethanol, hydrogen peroxide, peracetic acid, acidified sodium chlorite, and sodium hypochlorite in this study. The flushing with 500 mL of 1,000 ppm peracetic acid was most effective, reducing pathogens by 2.8 log CFU/cm<sup>2</sup>, followed by 1,200 ppm acidified sodium chlorite. The spraying with 1,000 ppm peracetic acid reduced pathogens by 1.6 log CFU/cm<sup>2</sup>. The flushing with 500 mL of 200 and 500 ppm acidified sodium chlorite, and 50, 100, 200, and 500 ppm peracetic acid significantly reduced the STEC population compared with those treated with distilled water (p < 0.05), reducing pathogens by 2.1, 2.4, 1.6, 1.8, 2.1 and 2.4 log CFU/cm<sup>2</sup>, respectively. Additionally, the flushing with 500 mL of 200 and 500 ppm acidified sodium chlorite significantly changed the color of beef samples (p < 0.05), whereas 100-500 ppm peracetic acid did not significantly change the color (p > 0.05). The flushing with 500 mL of 200 and 500 ppm acidified sodium chlorite and 200 and 500 ppm peracetic acid significantly changed the odor of beef samples compared with those treated with distilled water (p < 0.05). There was no difference in the reduction of STEC population between peracetic acid treatment at 25 °C and 55 °C, with or without washing with sterilized distilled water after decontamination. Washing with distilled water after flushing with peracetic acid tended to reduce the odor of the samples. These results suggest that treatment with 100, 200, and 500 ppm peracetic acid, followed by washing with distilled water, might reduce the STEC population without retaining the odor of the sanitizer.

Journal of Food ProtectionVol. 87(11)
Hoshi University (JP), National Institute of Health Sciences (JP), Ebara (Japan) (JP)
Zero hunger
Openalex Percentile: Top 27%
Escherichia coli research studies
0.62
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.