Impact of occluder device configurations in in-silico left atrial hemodynamics for the analysis of device-related thrombus

Left atrial appendage occlusion devices (LAAO) are a feasible alternative for non-valvular atrial fibrillation (AF) patients at high risk of thromboembolic stroke and contraindication to antithrombotic therapies. However, optimal LAAO device configurations (i.e., size, type, location) remain unstandardized due to the large anatomical variability of the left atrial appendage (LAA) morphology, leading to a 4-6% incidence of device-related thrombus (DRT). In-silico simulations have the potential to assess DRT risk and identify the key factors, such as suboptimal device positioning. This work presents fluid simulation results computed on 20 patient-specific left atrial geometries, analysing different commercially available LAAO occluders, including plug-type and pacifier-type devices. In addition, we explored two distinct device positions: 1) the real post-LAAO intervention configuration derived from follow-up imaging; and 2) one covering the pulmonary ridge if it was not achieved during the implantation (13 out of 20). In total, 33 different configurations were analysed. In-silico indices indicating high risk of DRT (e.g., low blood flow velocities and flow complexity around the device) were combined with particle deposition analysis based on a discrete phase model. The obtained results revealed that covering the pulmonary ridge with the LAAO device may be one of the key factors to prevent DRT, resulting in higher velocities and reduced flow recirculations (e.g., mean velocities of 0.183 ± 0.12 m/s and 0.236 ± 0.16 m/s for uncovered versus covered positions in DRT patients). Moreover, disk-based devices exhibited enhanced adaptability to various LAA morphologies and, generally, demonstrated a lower risk of abnormal events after LAAO implantation.

Authors

Institutions

Publication Details

Journal
PLoS Computational Biology
Published
2024-09-26
DOI
https://doi.org/10.1371/journal.pcbi.1011546
Citations
11
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
4.42

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of occluder device configurations in in-silico left atrial hemodynamics for the analysis of device-related thrombus

Hubert Cochet, Andy L. Olivares, Xavier Iriart, Carlos Albors et al.
11 citations
PLoS Computational Biology
Atrial Fibrillation Management and Outcomes
4.42
article

Impact of occluder device configurations in in-silico left atrial hemodynamics for the analysis of device-related thrombus

Hubert Cochet, Andy L. Olivares, Xavier Iriart, Carlos Albors, Óscar Cámara, Jordi Mill
article en
11 citations

Abstract

Left atrial appendage occlusion devices (LAAO) are a feasible alternative for non-valvular atrial fibrillation (AF) patients at high risk of thromboembolic stroke and contraindication to antithrombotic therapies. However, optimal LAAO device configurations (i.e., size, type, location) remain unstandardized due to the large anatomical variability of the left atrial appendage (LAA) morphology, leading to a 4-6% incidence of device-related thrombus (DRT). In-silico simulations have the potential to assess DRT risk and identify the key factors, such as suboptimal device positioning. This work presents fluid simulation results computed on 20 patient-specific left atrial geometries, analysing different commercially available LAAO occluders, including plug-type and pacifier-type devices. In addition, we explored two distinct device positions: 1) the real post-LAAO intervention configuration derived from follow-up imaging; and 2) one covering the pulmonary ridge if it was not achieved during the implantation (13 out of 20). In total, 33 different configurations were analysed. In-silico indices indicating high risk of DRT (e.g., low blood flow velocities and flow complexity around the device) were combined with particle deposition analysis based on a discrete phase model. The obtained results revealed that covering the pulmonary ridge with the LAAO device may be one of the key factors to prevent DRT, resulting in higher velocities and reduced flow recirculations (e.g., mean velocities of 0.183 ± 0.12 m/s and 0.236 ± 0.16 m/s for uncovered versus covered positions in DRT patients). Moreover, disk-based devices exhibited enhanced adaptability to various LAA morphologies and, generally, demonstrated a lower risk of abnormal events after LAAO implantation.

PLoS Computational BiologyVol. 20(9)
Inserm (FR), Universitat Pompeu Fabra (ES), Electrophysiology and Heart Modeling Institute (FR)
Ministerio de Ciencia, Innovación y Universidades, European Commission
Openalex Percentile: Top 5%
Atrial Fibrillation Management and Outcomes
4.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.