Dynamic optimization of boiler for minimizing energy consumption in the intentionally transient process operation: effect of different interval number

Abstract Certain manufacturing or industrial processes may involve variable conditions, and intentionally transient boiler operation allows optimal adaptation to these variations. This helps maintain efficiency and reduce energy consumption during different process phases. Transient operation is inherent during the start-up and intermittent phases in reaching the pressure required for boiler operation. Optimizing these transient states can reduce energy consumption. Dynamic optimization of boilers is crucial for several reasons, especially in industrial and power generation settings. Boilers are used to produce steam or hot water for various processes, and optimizing their performance can lead to increased efficiency, reduced energy consumption, and improved overall system reliability. The dynamic optimization problems were solved using the orthogonal collocation method. Three problem optimizations were considered in this study: minimize process time ( P 1), minimize energy consumption without optimized final time ( P 2), minimize energy consumption with optimized final time ( P 3). The control/decision variables applied were firing rate, Q , and water feed flowrate, q f . From the simulation results, the control trajectories of P 3 were chosen to be the most effective control operation to achieve the minimum energy consumption for reaching target pressure, i.e., 10.2 MPa, with a reasonable intermittent unit time. In practice, the selection of the number of intervals is often determined through a combination of domain knowledge, computational resources, and the desired level of accuracy. Sensitivity analysis and testing with different interval sizes can help in understanding the impact of this parameter on the optimization results. A greater interval time will decrease energy consumption.

Authors

Institutions

Publication Details

Journal
Chemical Product and Process Modeling
Published
2024-09-26
DOI
https://doi.org/10.1515/cppm-2024-0018
Citations
1
Primary Topic
Advanced Control Systems Optimization
Type
article
Field-Weighted Citation Impact
0.33

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dynamic optimization of boiler for minimizing energy consumption in the intentionally transient process operation: effect of different interval number

S. N. A. Ahmad Termizi, Ashraf Azmi‬‬‬‬‬, Sharifah Rafidah Wan Alwi, Hong An Er et al.
1 citations
Chemical Product and Process Modeling
Advanced Control Systems Optimization
0.33
article

Dynamic optimization of boiler for minimizing energy consumption in the intentionally transient process operation: effect of different interval number

S. N. A. Ahmad Termizi, Ashraf Azmi‬‬‬‬‬, Sharifah Rafidah Wan Alwi, Hong An Er, Fakhrony Sholahudin Rohman
article en
1 citations

Abstract

Abstract Certain manufacturing or industrial processes may involve variable conditions, and intentionally transient boiler operation allows optimal adaptation to these variations. This helps maintain efficiency and reduce energy consumption during different process phases. Transient operation is inherent during the start-up and intermittent phases in reaching the pressure required for boiler operation. Optimizing these transient states can reduce energy consumption. Dynamic optimization of boilers is crucial for several reasons, especially in industrial and power generation settings. Boilers are used to produce steam or hot water for various processes, and optimizing their performance can lead to increased efficiency, reduced energy consumption, and improved overall system reliability. The dynamic optimization problems were solved using the orthogonal collocation method. Three problem optimizations were considered in this study: minimize process time ( P 1), minimize energy consumption without optimized final time ( P 2), minimize energy consumption with optimized final time ( P 3). The control/decision variables applied were firing rate, Q , and water feed flowrate, q f . From the simulation results, the control trajectories of P 3 were chosen to be the most effective control operation to achieve the minimum energy consumption for reaching target pressure, i.e., 10.2 MPa, with a reasonable intermittent unit time. In practice, the selection of the number of intervals is often determined through a combination of domain knowledge, computational resources, and the desired level of accuracy. Sensitivity analysis and testing with different interval sizes can help in understanding the impact of this parameter on the optimization results. A greater interval time will decrease energy consumption.

Chemical Product and Process ModelingVol. 19(5)
University of Technology Malaysia (MY), Universiti Malaysia Perlis (MY), Universiti Teknologi MARA (MY)
Universiti Teknologi Malaysia
Openalex Percentile: Top 42%
Advanced Control Systems Optimization
0.33
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.