Flexible Low-Dose X-Ray Detector Based on YAG Crystal-Derived Scintillation Silicate Fiber Doped With Ce³+, Tb³+, and Gd³+

A low-dose X-ray detector based on a novel Ce3+, Tb3+, and Gd3+ co-doped YAG crystal-derived scintillation fiber (CTGYCF) was demonstrated. The CTGYCF, featuring an yttrium aluminosilicate glass core and SiO2 cladding, was prepared using the melt-in-tube (MIT) method. The effective atomic number (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$Z_{\text {eff}}$ </tex-math></inline-formula>) of the CTGYCF core reaches 29.59, and the average insertion loss of the splicing between CTGYCF and commercial transmission quartz fiber (MMF) is 0.013 dB. The CTGYCF exhibits higher luminescence intensity under 245-nm excitation due to efficient energy transfer from Gd3+ and Ce3+ to Tb3+. Leveraging the CTGYCF’s high <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$Z_{\text {eff}}$ </tex-math></inline-formula>, high optical yield, and low connection loss, the detector realized real-time monitoring of low-dose X-ray. For low-dose X-rays in the range of 1.13–<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$3.06 \; \mu $ </tex-math></inline-formula>Gy/s, the detector demonstrated an excellent linear response with an R2 value of ~0.997. Its X-ray response remained highly stable as the dose rate increased from 12.24 to <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$30.74 \; \mu $ </tex-math></inline-formula>Gy/s. Given its performance, the CTGYCF-based detector shows great potential for remote real-time monitoring of low-dose X-ray in inaccessible or hazardous environments.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2024-09-26
DOI
https://doi.org/10.1109/jsen.2024.3463749
Citations
1
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.61

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Flexible Low-Dose X-Ray Detector Based on YAG Crystal-Derived Scintillation Silicate Fiber Doped With Ce³+, Tb³+, and Gd³+

Zhigang Zhao, Xian Zhao, Zhaojun Liu, Zhenhua Cong et al.
1 citations
IEEE Sensors Journal
Radiation Detection and Scintillator Technologies
0.61
article

Flexible Low-Dose X-Ray Detector Based on YAG Crystal-Derived Scintillation Silicate Fiber Doped With Ce³+, Tb³+, and Gd³+

Zhigang Zhao, Xian Zhao, Zhaojun Liu, Zhenhua Cong, Zhenshuai Wei, X. Wu, Haiyan Li, Lu Huang
article en
1 citations

Abstract

A low-dose X-ray detector based on a novel Ce3+, Tb3+, and Gd3+ co-doped YAG crystal-derived scintillation fiber (CTGYCF) was demonstrated. The CTGYCF, featuring an yttrium aluminosilicate glass core and SiO2 cladding, was prepared using the melt-in-tube (MIT) method. The effective atomic number (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$Z_{\text {eff}}$ </tex-math></inline-formula>) of the CTGYCF core reaches 29.59, and the average insertion loss of the splicing between CTGYCF and commercial transmission quartz fiber (MMF) is 0.013 dB. The CTGYCF exhibits higher luminescence intensity under 245-nm excitation due to efficient energy transfer from Gd3+ and Ce3+ to Tb3+. Leveraging the CTGYCF’s high <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$Z_{\text {eff}}$ </tex-math></inline-formula>, high optical yield, and low connection loss, the detector realized real-time monitoring of low-dose X-ray. For low-dose X-rays in the range of 1.13–<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$3.06 \; \mu $ </tex-math></inline-formula>Gy/s, the detector demonstrated an excellent linear response with an R2 value of ~0.997. Its X-ray response remained highly stable as the dose rate increased from 12.24 to <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$30.74 \; \mu $ </tex-math></inline-formula>Gy/s. Given its performance, the CTGYCF-based detector shows great potential for remote real-time monitoring of low-dose X-ray in inaccessible or hazardous environments.

IEEE Sensors JournalVol. 24(22)
Ministry of Education of the People's Republic of China (CN), Shandong University (CN), Shandong Institute of Metrology (CN), Ministry of Education (ME)
National Natural Science Foundation of China
Openalex Percentile: Top 31%
Radiation Detection and Scintillator Technologies
0.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.