Measurement of noise emitted by power equipment based on coherent power

Measuring the noise emitted by power equipment requires measuring the total environment noise and background noise. Due to it being impossible to shut down the power equipment to measure background noise, the noise emission of power equipment cannot be measured accurately. This work conducts research on noise emission of power equipment based on coherent power. Firstly, a test in the lab was conducted to measure the noise emitted by two speakers based on coherent power. This test showed that the measurement error was less than 1 dB(A). Subsequently, the measurement of noise emitted by power equipment was carried out in a 500 kV substation, and the results showed that the measurement error was also less than 1 dB(A). Through measurements in the lab and substation, it has been verified that the coherent power method can accurately measure the noise emitted by power equipment, avoiding the error caused by inaccurate measurement of background noise.

Authors

Institutions

Publication Details

Published
2024-09-26
DOI
https://doi.org/10.1117/12.3044794
Primary Topic
Electromagnetic Compatibility and Noise Suppression
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurement of noise emitted by power equipment based on coherent power

Shengping Fan, Hualiang Li, Linyong Li, Yifan Wang et al.
Electromagnetic Compatibility and Noise Suppression
article

Measurement of noise emitted by power equipment based on coherent power

Shengping Fan, Hualiang Li, Linyong Li, Yifan Wang, Yali Shen, Li Li, Ziyue Lin
article en

Abstract

Measuring the noise emitted by power equipment requires measuring the total environment noise and background noise. Due to it being impossible to shut down the power equipment to measure background noise, the noise emission of power equipment cannot be measured accurately. This work conducts research on noise emission of power equipment based on coherent power. Firstly, a test in the lab was conducted to measure the noise emitted by two speakers based on coherent power. This test showed that the measurement error was less than 1 dB(A). Subsequently, the measurement of noise emitted by power equipment was carried out in a 500 kV substation, and the results showed that the measurement error was also less than 1 dB(A). Through measurements in the lab and substation, it has been verified that the coherent power method can accurately measure the noise emitted by power equipment, avoiding the error caused by inaccurate measurement of background noise.

Electric Power Research Institute (US), China Southern Power Grid (China) (CN), Power Grid Corporation (India) (IN)
China Southern Power Grid
Affordable and clean energy
Openalex Percentile: Top 86%
Electromagnetic Compatibility and Noise Suppression
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.