Effects of various parameters on guidewire and catheter behavior during catheter introduction

Many guidewire penetration accidents occur during catheter introduction. Therefore, we have evaluated the behavior of medical devices such as guidewires and catheters during catheter introduction using numerical simulations. In our previous study, we evaluated the effects of the insertion velocity of the guidewire and the catheter and confirmed that during catheter introduction, the guidewire imparted a greater load on the vessel wall than that exerted by the guidewire alone. However, it was unclear whether the above phenomenon could also occur under other conditions. In the present study, in addition to these effects, we evaluate the effects of the blood vessel elastic modulus, device insertion length, blood vessel centerline curvature, and their interactions. Furthermore, we evaluate the behavior of the medical devices during guidewire removal after catheter introduction, which was not evaluated in our previous study. We determine the simulation conditions based on the design of experiments and investigate the dominant parameters that affect the contact force between the medical devices and the blood vessel wall using two methods (one that considers parameter interactions and one that does not). We confirm that during guidewire insertion and removal, the device velocity and the vessel centerline curvature have the largest effects, respectively. For the guidewire and the catheter during catheter introduction, the vessel elastic modulus and the insertion velocity have the largest effects, respectively, and the parameter interactions have large effects. These findings are clinically important because they are counterintuitive. During catheter introduction, the average contact forces are larger than those during both guidewire insertion and removal. Furthermore, during guidewire removal, the catheter tip moves in the distal direction.

Authors

Institutions

Publication Details

Journal
Journal of Biomechanical Science and Engineering
Published
2024-09-26
DOI
https://doi.org/10.1299/jbse.24-00230
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of various parameters on guidewire and catheter behavior during catheter introduction

Kazuto TAKASHIMA, Koji Mori, Masaaki Shojima, Naoki Toma et al.
Journal of Biomechanical Science and Engineering
Central Venous Catheters and Hemodialysis
article

Effects of various parameters on guidewire and catheter behavior during catheter introduction

Kazuto TAKASHIMA, Koji Mori, Masaaki Shojima, Naoki Toma, Yoichi Haga, Makoto Ohta, Akinori NAMBA, Hiroto HIDAKA
article en

Abstract

Many guidewire penetration accidents occur during catheter introduction. Therefore, we have evaluated the behavior of medical devices such as guidewires and catheters during catheter introduction using numerical simulations. In our previous study, we evaluated the effects of the insertion velocity of the guidewire and the catheter and confirmed that during catheter introduction, the guidewire imparted a greater load on the vessel wall than that exerted by the guidewire alone. However, it was unclear whether the above phenomenon could also occur under other conditions. In the present study, in addition to these effects, we evaluate the effects of the blood vessel elastic modulus, device insertion length, blood vessel centerline curvature, and their interactions. Furthermore, we evaluate the behavior of the medical devices during guidewire removal after catheter introduction, which was not evaluated in our previous study. We determine the simulation conditions based on the design of experiments and investigate the dominant parameters that affect the contact force between the medical devices and the blood vessel wall using two methods (one that considers parameter interactions and one that does not). We confirm that during guidewire insertion and removal, the device velocity and the vessel centerline curvature have the largest effects, respectively. For the guidewire and the catheter during catheter introduction, the vessel elastic modulus and the insertion velocity have the largest effects, respectively, and the parameter interactions have large effects. These findings are clinically important because they are counterintuitive. During catheter introduction, the average contact forces are larger than those during both guidewire insertion and removal. Furthermore, during guidewire removal, the catheter tip moves in the distal direction.

Journal of Biomechanical Science and EngineeringVol. 20(1)
Yamaguchi University (JP), Mie University (JP), Tohoku University (JP), Kyushu Institute of Technology (JP), Teikyo University (JP)
Forskningsrådet om Hälsa, Arbetsliv och Välfärd
Zero hunger
Openalex Percentile: Top 72%
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.