Microbubble-laden aerosols improve post-nasal aerosol penetration efficiency in a preterm neonate model

Nebulized lung surfactant therapy has been a neonatology long-pursued goal. Nevertheless, many clinical trials have yet to show a clear clinical efficacy of nebulized surfactant, which, in part, is due to the technical challenges of delivering aerosols to the lungs of preterm neonates. The study aimed to test microbubbles for improving lung deposition in preterm neonates. An in vitro testing method was developed to replicate the clinical environment; it used a 3D-printed preterm neonate model, connected to a high-flow nasal cannula (HFNC) and a vibrating mesh nebulizer. The flow rate of the HFNC mirrored that used in the clinics (i.e., 4, 6, and 8 L/min). Followingly, the lung penetrations of aerosols with and without microbubbles were compared. The aerodynamic diameter of aerosols with microbubbles (MMAD=1.75 μm) was lower than that of the counterpart (MMAD=2.25 μm). Microbubble-laden aerosols had a significantly higher number of microbubbles that were below 1.0 μm. Microbubble-laden aerosols had dramatically higher lung penetration in the preterm model; lung penetration efficiencies were 30.0, 25.5, and 17.5 % at 4, 6, and 8 L/min, respectively, whereas the lung penetration efficiency for conventionally nebulized aerosols was below 1.25 % in the three flow rates.

Authors

Institutions

Publication Details

Journal
International Journal of Pharmaceutics
Published
2024-09-27
DOI
https://doi.org/10.1016/j.ijpharm.2024.124772
Citations
1
Primary Topic
Neonatal Respiratory Health Research
Type
article
Field-Weighted Citation Impact
0.42

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microbubble-laden aerosols improve post-nasal aerosol penetration efficiency in a preterm neonate model

Stephen J. Payne, Hyunhong J Min, Eleanor Stride, Xinghao Cheng
1 citations
International Journal of Pharmaceutics
Neonatal Respiratory Health Research
0.42
article

Microbubble-laden aerosols improve post-nasal aerosol penetration efficiency in a preterm neonate model

Stephen J. Payne, Hyunhong J Min, Eleanor Stride, Xinghao Cheng
article en
1 citations

Abstract

Nebulized lung surfactant therapy has been a neonatology long-pursued goal. Nevertheless, many clinical trials have yet to show a clear clinical efficacy of nebulized surfactant, which, in part, is due to the technical challenges of delivering aerosols to the lungs of preterm neonates. The study aimed to test microbubbles for improving lung deposition in preterm neonates. An in vitro testing method was developed to replicate the clinical environment; it used a 3D-printed preterm neonate model, connected to a high-flow nasal cannula (HFNC) and a vibrating mesh nebulizer. The flow rate of the HFNC mirrored that used in the clinics (i.e., 4, 6, and 8 L/min). Followingly, the lung penetrations of aerosols with and without microbubbles were compared. The aerodynamic diameter of aerosols with microbubbles (MMAD=1.75 μm) was lower than that of the counterpart (MMAD=2.25 μm). Microbubble-laden aerosols had a significantly higher number of microbubbles that were below 1.0 μm. Microbubble-laden aerosols had dramatically higher lung penetration in the preterm model; lung penetration efficiencies were 30.0, 25.5, and 17.5 % at 4, 6, and 8 L/min, respectively, whereas the lung penetration efficiency for conventionally nebulized aerosols was below 1.25 % in the three flow rates.

International Journal of PharmaceuticsVol. 666
National Taiwan University (TW), University of Oxford (GB), Science Oxford (GB)
University of Oxford
Affordable and clean energy
Openalex Percentile: Top 33%
Neonatal Respiratory Health Research
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.