Uncertainty quantification: For an IAQ and energy performance assessment method for smart ventilation strategies

In new low-energy buildings or buildings after thermal refurbishment, the envelope high airtightness could have an impact on air renewal and could decrease the indoor air quality (IAQ). In this context smart-ventilation systems with variable airflows could play a role in providing better IAQ without compromising the energy performance. However, smart-ventilation strategies are quite recent, and their benefits need to be clearly quantified. This article, proposes to quantify the uncertainty of a recent multi-criteria performance assessment method, using global RBD-FAST sensitivity analysis. The impact of the pollutant emissions scenarios, model input parameters and ventilation strategies is assessed. Five ventilation systems were studied: two constant airflow, one humidity-controlled and two humidity/CO2 controlled, applied on a French low-energy house. 2500 simulations were performed to calculate 504 sensitivity indices across 12 input variables and 9 output performance indicators. The sensitivity analysis shows that occupant bio-effluent, formaldehyde and PM2.5 emissions rates are responsible for 11 %–87 % of the uncertainty for the IAQ performance indicators. The PM2.5 deposition velocity parameter is responsible for 50 % of the uncertainty on the PM2.5 indicator, which was an unknown impact. In addition, the benefits of humidity-controlled ventilation were highlighted regarding energy performance, with, in average, 20 % lower heat-loss compared to constant airflow ventilation. Moreover, smart-ventilation provides clear IAQ benefits without drastically increasing the energy demand. This work demonstrates the potential of the proposed evaluation method for ventilation performance assessment. • PM2.5 deposition velocity is the main factor influencing the PM2.5 IAQ indicator. • Short-term IAQ indicators provide no additional information to long-term indicators. • Reference emission scenario does not always give median or average results. • Humidity-based control offers, in average, 20 % less heat losses than constant airflow. • With smart ventilation, there is an IAQ benefit on the CO2, but heat recovery is need.

Authors

Institutions

Publication Details

Journal
Building and Environment
Published
2024-09-26
DOI
https://doi.org/10.1016/j.buildenv.2024.112115
Citations
13
Primary Topic
Probabilistic and Robust Engineering Design
Type
article
Field-Weighted Citation Impact
6.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Uncertainty quantification: For an IAQ and energy performance assessment method for smart ventilation strategies

Gaëlle Guyot, Baptiste Poirier, Monika Woloszyn
13 citations
Building and Environment
Probabilistic and Robust Engineering Design
6.00
article

Uncertainty quantification: For an IAQ and energy performance assessment method for smart ventilation strategies

Gaëlle Guyot, Baptiste Poirier, Monika Woloszyn
article en
13 citations

Abstract

In new low-energy buildings or buildings after thermal refurbishment, the envelope high airtightness could have an impact on air renewal and could decrease the indoor air quality (IAQ). In this context smart-ventilation systems with variable airflows could play a role in providing better IAQ without compromising the energy performance. However, smart-ventilation strategies are quite recent, and their benefits need to be clearly quantified. This article, proposes to quantify the uncertainty of a recent multi-criteria performance assessment method, using global RBD-FAST sensitivity analysis. The impact of the pollutant emissions scenarios, model input parameters and ventilation strategies is assessed. Five ventilation systems were studied: two constant airflow, one humidity-controlled and two humidity/CO2 controlled, applied on a French low-energy house. 2500 simulations were performed to calculate 504 sensitivity indices across 12 input variables and 9 output performance indicators. The sensitivity analysis shows that occupant bio-effluent, formaldehyde and PM2.5 emissions rates are responsible for 11 %–87 % of the uncertainty for the IAQ performance indicators. The PM2.5 deposition velocity parameter is responsible for 50 % of the uncertainty on the PM2.5 indicator, which was an unknown impact. In addition, the benefits of humidity-controlled ventilation were highlighted regarding energy performance, with, in average, 20 % lower heat-loss compared to constant airflow ventilation. Moreover, smart-ventilation provides clear IAQ benefits without drastically increasing the energy demand. This work demonstrates the potential of the proposed evaluation method for ventilation performance assessment. • PM2.5 deposition velocity is the main factor influencing the PM2.5 IAQ indicator. • Short-term IAQ indicators provide no additional information to long-term indicators. • Reference emission scenario does not always give median or average results. • Humidity-based control offers, in average, 20 % less heat losses than constant airflow. • With smart ventilation, there is an IAQ benefit on the CO2, but heat recovery is need.

Building and EnvironmentVol. 266
Centre National de la Recherche Scientifique (FR), Arkema (France) (FR), Laboratoire Optimisation de la Conception et Ingénierie de l'Environnement (FR), École Nationale des Travaux Publics de l'État (FR), Université Savoie Mont Blanc (FR)
Affordable and clean energy
Openalex Percentile: Top 4%
Probabilistic and Robust Engineering Design
6.00
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.