Uncertainty Evaluation for the Determination of Perfluorinated Compounds in Wastewater Treatment Facility Effluent

This study evaluates the sources of uncertainty in the determination of poly & perfluorinated compounds(PFHxS, PFOS, PFOA) in the effluent of a wastewater treatment facility using LC-MS/MS. The uncertainty sources were identified and, numerically quantified, and the overall uncertainty of the final results was calculated through the synthesis and expansion of uncertainties. The main factors contributing to the combined standard uncertainty were identified as the construction of calibration curves, the reproducibility uncertainty from repeated tests, and the uncertainty associated with sample collection. By contrast, the effects of processes such as the volume filling of 1 mL standards after concentration and the injection of internal standards were found to be negligible. The relative expanded uncertainties for the three perfluorinated compounds were within 7.45%. The contributions to the overall uncertainty from sample collection, calibration curve construction, internal standard injection, volume filling of 1 mL standards, and reproducibility from repeat tests were 1.16~1.62%, 87.11~94.52%, 0.37~0.53%, 0.33~0.46%, 2.87~11.03%, respectively.

Authors

Publication Details

Journal
Journal of Environmental Analysis Health and Toxicology
Published
2024-09-27
DOI
https://doi.org/10.36278/jeaht.27.3.123
Primary Topic
Environmental Policies and Emissions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Uncertainty Evaluation for the Determination of Perfluorinated Compounds in Wastewater Treatment Facility Effluent

Jin‐Young Lee, Sun-hee Jung, Sun-min Hwang, C. L. Hwang et al.
Journal of Environmental Analysis Health and Toxicology
Environmental Policies and Emissions
article

Uncertainty Evaluation for the Determination of Perfluorinated Compounds in Wastewater Treatment Facility Effluent

Jin‐Young Lee, Sun-hee Jung, Sun-min Hwang, C. L. Hwang, Phil-kweon Choi, Su-jung Seo
article en

Abstract

This study evaluates the sources of uncertainty in the determination of poly & perfluorinated compounds(PFHxS, PFOS, PFOA) in the effluent of a wastewater treatment facility using LC-MS/MS. The uncertainty sources were identified and, numerically quantified, and the overall uncertainty of the final results was calculated through the synthesis and expansion of uncertainties. The main factors contributing to the combined standard uncertainty were identified as the construction of calibration curves, the reproducibility uncertainty from repeated tests, and the uncertainty associated with sample collection. By contrast, the effects of processes such as the volume filling of 1 mL standards after concentration and the injection of internal standards were found to be negligible. The relative expanded uncertainties for the three perfluorinated compounds were within 7.45%. The contributions to the overall uncertainty from sample collection, calibration curve construction, internal standard injection, volume filling of 1 mL standards, and reproducibility from repeat tests were 1.16~1.62%, 87.11~94.52%, 0.37~0.53%, 0.33~0.46%, 2.87~11.03%, respectively.

Journal of Environmental Analysis Health and ToxicologyVol. 27(3)
Openalex Percentile: Top 90%
Environmental Policies and Emissions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.