Non-contact multiangle jujube quality quantitative detection device based on light field regulation

With the simultaneous development of jujube industry and intelligent agriculture, there is an increasing demand for collecting pre-evaluation of jujube quality using high technology. This paper proposes a non-contact multi-angle red jujube quality quantitative detection device based on light field modulation. This device realizes non-contact theoretical telemetry by superimposing multiple lenses in front of the spectrometer and uses the spatial light modulator SLM to change the size of the light field spot in order to change the detection range of the light field, and to explore the precision of red date quality detection under different light spots at multiple angles. After experimental verification, the moisture content of jujube tested by the detection device, the correlation coefficient of jujube correction set is 0.743, the correlation coefficient of prediction set is 0.694, and the average absolute error is 1.190%. The overall can make a preliminary judgment on the quality of jujube.

Authors

Institutions

Publication Details

Published
2024-09-27
DOI
https://doi.org/10.1117/12.3045632
Primary Topic
Remote Sensing and Land Use
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Non-contact multiangle jujube quality quantitative detection device based on light field regulation

Lei Kang, YaBei Di, HuaPing Luo, HongYang Liu et al.
Remote Sensing and Land Use
article

Non-contact multiangle jujube quality quantitative detection device based on light field regulation

Lei Kang, YaBei Di, HuaPing Luo, HongYang Liu, HuaiYu Liu, YueSen Tong
article en

Abstract

With the simultaneous development of jujube industry and intelligent agriculture, there is an increasing demand for collecting pre-evaluation of jujube quality using high technology. This paper proposes a non-contact multi-angle red jujube quality quantitative detection device based on light field modulation. This device realizes non-contact theoretical telemetry by superimposing multiple lenses in front of the spectrometer and uses the spatial light modulator SLM to change the size of the light field spot in order to change the detection range of the light field, and to explore the precision of red date quality detection under different light spots at multiple angles. After experimental verification, the moisture content of jujube tested by the detection device, the correlation coefficient of jujube correction set is 0.743, the correlation coefficient of prediction set is 0.694, and the average absolute error is 1.190%. The overall can make a preliminary judgment on the quality of jujube.

Tarim University (CN)
Openalex Percentile: Top 80%
Remote Sensing and Land Use
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.