International inter-laboratory comparison of solar heat gain coefficient of building-integrated photovoltaic modules - results of tests with or without power generation and tests with PV cell coverage ratios

The solar heat gain coefficient is one of the important indicators to evaluate the performance of the building envelope components. In a BIPV module, secondary heat transfer to the indoors is reduced, compared to conventional glazing, due to the shielding effect of the PV cells and energy conversion by power generation. There is a difference in SHGC between power-generating (MPP) and effectively open-circuit (OC) states. In this paper, in order to prepare a calorimetric SHGC evaluation methodology for BIPV modules, we documented the current status of the experimental calorimetric test methods and test apparatus adopted by test laboratories in four different countries and identified the differences. Differences between the test laboratories were found in the applied test methods, solar simulator types, spectral distributions, irradiation inhomogeneity on the light-receiving surface of the test sample, temperature conditions between the test chamber and the metering box, and surface heat transfer coefficients. Especially, the round-robin test results obtained in an interlaboratory comparison clarified that the differences in the characteristics of the Calorimetic Hot Box and the Heat Flux Metering methodologies with a cooled plate, the differences in irradiation inhomogeneity on the light-receiving surface of the test sample and differences in surface heat transfer coefficients significantly affect the SHGC evaluation for BIPV modules. In addition, for the SHGC test in the MPP state, it was confirmed that an absolute SHGC reduction effect of 0.02 to 0.04 was obtained for a PV laminate with 81 % cell coverage, for all SHGC test methods and test apparatus. P e characterises the effect of converting part of the sunlight absorbed by the PV cell into electric power and extracting it from the BIPV module, reducing the heat re-radiated indoors compared to the OC state. Due to this mechanism, the reduction effect P e always occurs during power generation, regardless of the type of PV cell technology and whether the PV cells are opaque or transparent. In addition, the decrease in SHGC for a given glazing configuration was found to be proportional to the increase in PV cell coverage ratio. SHGC tests with four different cell coverage ratios confirmed that the relationship between PV cell coverage ratio and SHGC is linear to a high degree of accuracy when no electric power is extracted (OC state), provided that the incident radiation is spatially homogeneous. The results obtained will be useful when proposing a calorimetric SHGC evaluation methodology for international standardization, as they document the differences due to a range of test facilities and testing conditions, differences caused by power generation and extraction, and the effect of varying PV cell coverage ratios. The insights gained were valuable in identifying which aspects of test methodology and boundary conditions must be specified with particular attention to detail when calorimetric testing standards are extended to explicitly address the SHGC determination of BIPV modules.

Authors

Institutions

Publication Details

Journal
Energy and Buildings
Published
2024-09-26
DOI
https://doi.org/10.1016/j.enbuild.2024.114843
Citations
5
Primary Topic
Photovoltaic System Optimization Techniques
Type
article
Field-Weighted Citation Impact
0.51

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

International inter-laboratory comparison of solar heat gain coefficient of building-integrated photovoltaic modules - results of tests with or without power generation and tests with PV cell coverage ratios

Ulrich Amann, Helen Rose Wilson, Hisashi Ishii, Veronika Shabunko et al.
5 citations
Energy and Buildings
Photovoltaic System Optimization Techniques
0.51
article

International inter-laboratory comparison of solar heat gain coefficient of building-integrated photovoltaic modules - results of tests with or without power generation and tests with PV cell coverage ratios

Ulrich Amann, Helen Rose Wilson, Hisashi Ishii, Veronika Shabunko, Simon Boddaert, S Hagihara
article en
5 citations

Abstract

The solar heat gain coefficient is one of the important indicators to evaluate the performance of the building envelope components. In a BIPV module, secondary heat transfer to the indoors is reduced, compared to conventional glazing, due to the shielding effect of the PV cells and energy conversion by power generation. There is a difference in SHGC between power-generating (MPP) and effectively open-circuit (OC) states. In this paper, in order to prepare a calorimetric SHGC evaluation methodology for BIPV modules, we documented the current status of the experimental calorimetric test methods and test apparatus adopted by test laboratories in four different countries and identified the differences. Differences between the test laboratories were found in the applied test methods, solar simulator types, spectral distributions, irradiation inhomogeneity on the light-receiving surface of the test sample, temperature conditions between the test chamber and the metering box, and surface heat transfer coefficients. Especially, the round-robin test results obtained in an interlaboratory comparison clarified that the differences in the characteristics of the Calorimetic Hot Box and the Heat Flux Metering methodologies with a cooled plate, the differences in irradiation inhomogeneity on the light-receiving surface of the test sample and differences in surface heat transfer coefficients significantly affect the SHGC evaluation for BIPV modules. In addition, for the SHGC test in the MPP state, it was confirmed that an absolute SHGC reduction effect of 0.02 to 0.04 was obtained for a PV laminate with 81 % cell coverage, for all SHGC test methods and test apparatus. P e characterises the effect of converting part of the sunlight absorbed by the PV cell into electric power and extracting it from the BIPV module, reducing the heat re-radiated indoors compared to the OC state. Due to this mechanism, the reduction effect P e always occurs during power generation, regardless of the type of PV cell technology and whether the PV cells are opaque or transparent. In addition, the decrease in SHGC for a given glazing configuration was found to be proportional to the increase in PV cell coverage ratio. SHGC tests with four different cell coverage ratios confirmed that the relationship between PV cell coverage ratio and SHGC is linear to a high degree of accuracy when no electric power is extracted (OC state), provided that the incident radiation is spatially homogeneous. The results obtained will be useful when proposing a calorimetric SHGC evaluation methodology for international standardization, as they document the differences due to a range of test facilities and testing conditions, differences caused by power generation and extraction, and the effect of varying PV cell coverage ratios. The insights gained were valuable in identifying which aspects of test methodology and boundary conditions must be specified with particular attention to detail when calorimetric testing standards are extended to explicitly address the SHGC determination of BIPV modules.

Energy and BuildingsVol. 329
EURECOM (FR), Energy Research Institute (RU), Fraunhofer Institute for Solar Energy Systems (DE), Electronics Testing Center (TW), Advanced Institute of Industrial Technology (JP)
New Energy and Industrial Technology Development Organization
Affordable and clean energy
Openalex Percentile: Top 43%
Photovoltaic System Optimization Techniques
0.51
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.