Radiation dose in cardiac CT for preoperative diagnosis of children with congenital heart disease

Abstract Background One of the most common congenital conditions detected globally, congenital heart diseases, and CT techniques provide a high-quality and thorough presentation of heart anatomy, thoracic vasculature, and extracardiac structures, and hence, it is becoming a more popular non-invasive diagnostic imaging method for congenital heart disease. The drawbacks with CT imaging are the radiation exposure from repeated scans is also rising, especially in young patients. The present study is aimed to evaluate the radiation dose in gated and non-gated cardiac CT for preoperative diagnosis of pediatric patients with congenital heart diseases. Results A total of 111 pediatric patients with mean age of 7.47 years were prospectively included in the study. The mean value of “Effective dose (E)” for gated CT at $$100\;{\text{kV}}_{{\text{p}}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mn>100</mml:mn> <mml:mspace/> <mml:msub> <mml:mtext>kV</mml:mtext> <mml:mtext>p</mml:mtext> </mml:msub> </mml:mrow> </mml:math> was found to be $$4.71\;{\text{mSv}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mn>4.71</mml:mn> <mml:mspace/> <mml:mtext>mSv</mml:mtext> </mml:mrow> </mml:math> which is higher than mean “E” of $$3.95\;{\text{mSv}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mn>3.95</mml:mn> <mml:mspace/> <mml:mtext>mSv</mml:mtext> </mml:mrow> </mml:math> observed for gated CT at $$80\;{\text{kV}}_{{\text{p}}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mn>80</mml:mn> <mml:mspace/> <mml:msub> <mml:mtext>kV</mml:mtext> <mml:mtext>p</mml:mtext> </mml:msub> </mml:mrow> </mml:math> . The average value of “E” for non-gated technique was observed less than that of gated technique at both $$100\;{\text{kV}}_{{\text{p}}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mn>100</mml:mn> <mml:mspace/> <mml:msub> <mml:mtext>kV</mml:mtext> <mml:mtext>p</mml:mtext> </mml:msub> </mml:mrow> </mml:math> and $$80\;{\text{kV}}_{{\text{p}}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mn>80</mml:mn> <mml:mspace/> <mml:msub> <mml:mtext>kV</mml:mtext> <mml:mtext>p</mml:mtext> </mml:msub> </mml:mrow> </mml:math> . The multiple regression analysis shows that “E” is significantly dependent on $${\text{DLP}}\left( {{\text{mGy}}\;{\text{cm}}} \right)$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mtext>DLP</mml:mtext> <mml:mfenced> <mml:mrow> <mml:mtext>mGy</mml:mtext> <mml:mspace/> <mml:mtext>cm</mml:mtext> </mml:mrow> </mml:mfenced> </mml:mrow> </mml:math> for both gated and non-gated techniques at 95% level of significance $$\left( {p &lt; 0.05} \right)$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mfenced> <mml:mrow> <mml:mi>p</mml:mi> <mml:mo>&lt;</mml:mo> <mml:mn>0.05</mml:mn> </mml:mrow> </mml:mfenced> </mml:math> . The Student’s t-test verifies that the mean value of “E” for both the techniques at $$100\;{\text{kV}}_{{\text{p}}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mn>100</mml:mn> <mml:mspace/> <mml:msub> <mml:mtext>kV</mml:mtext> <mml:mtext>p</mml:mtext> </mml:msub> </mml:mrow> </mml:math> and $$80\;{\text{kV}}_{{\text{p}}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mn>80</mml:mn> <mml:mspace/> <mml:msub> <mml:mtext>kV</mml:mtext> <mml:mtext>p</mml:mtext> </mml:msub> </mml:mrow> </mml:math> are significantly different at 95% level of significance $$\left( {p &lt; 0.05} \right)$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mfenced> <mml:mrow> <mml:mi>p</mml:mi> <mml:mo>&lt;</mml:mo> <mml:mn>0.05</mml:mn> </mml:mrow> </mml:mfenced> </mml:math> . Conclusions The effective dose received by pediatric patients is much higher when using ECG-gated acquisition with an average value of $$4.71\;{\text{mSv}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mn>4.71</mml:mn> <mml:mspace/> <mml:mtext>mSv</mml:mtext> </mml:mrow> </mml:math> and $$3.95\;{\text{mSv}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mn>3.95</mml:mn> <mml:mspace/> <mml:mtext>mSv</mml:mtext> </mml:mrow> </mml:math> at $$100\;{\text{kV}}_{{\text{p}}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mn>100</mml:mn> <mml:mspace/> <mml:msub> <mml:mtext>kV</mml:mtext> <mml:mtext>p</mml:mtext> </mml:msub> </mml:mrow> </mml:math> , and at $$80\;{\text{kV}}_{{\text{p}}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mn>80</mml:mn> <mml:mspace/> <mml:msub> <mml:mtext>kV</mml:mtext> <mml:mtext>p</mml:mtext> </mml:msub> </mml:mrow> </mml:math> respectively. Because low-voltage X-rays are more sensitive to high atomic number iodinated contrast media, the mean “E” for non-gated cardiac CT imaging at $$80\;{\text{kV}}_{{\text{p}}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mn>80</mml:mn> <mml:mspace/> <mml:msub> <mml:mtext>kV</mml:mtext> <mml:mtext>p</m

Authors

Institutions

Publication Details

Journal
The Egyptian Journal of Radiology and Nuclear Medicine
Published
2024-09-26
DOI
https://doi.org/10.1186/s43055-024-01368-y
Citations
4
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
1.62
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Radiation dose in cardiac CT for preoperative diagnosis of children with congenital heart disease

Mehtab Ahmad, Mudasir Ashraf Shah, Samreen Shahid, Shaad Abqari et al.
4 citations
The Egyptian Journal of Radiology and Nuclear Medicine
Radiation Dose and Imaging
1.62
article

Radiation dose in cardiac CT for preoperative diagnosis of children with congenital heart disease

Mehtab Ahmad, Mudasir Ashraf Shah, Samreen Shahid, Shaad Abqari, Syed Yusuf Masood
article en
4 citations

Abstract

Abstract Background One of the most common congenital conditions detected globally, congenital heart diseases, and CT techniques provide a high-quality and thorough presentation of heart anatomy, thoracic vasculature, and extracardiac structures, and hence, it is becoming a more popular non-invasive diagnostic imaging method for congenital heart disease. The drawbacks with CT imaging are the radiation exposure from repeated scans is also rising, especially in young patients. The present study is aimed to evaluate the radiation dose in gated and non-gated cardiac CT for preoperative diagnosis of pediatric patients with congenital heart diseases. Results A total of 111 pediatric patients with mean age of 7.47 years were prospectively included in the study. The mean value of “Effective dose (E)” for gated CT at $$100\;{\text{kV}}_{{\text{p}}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mn>100</mml:mn> <mml:mspace/> <mml:msub> <mml:mtext>kV</mml:mtext> <mml:mtext>p</mml:mtext> </mml:msub> </mml:mrow> </mml:math> was found to be $$4.71\;{\text{mSv}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mn>4.71</mml:mn> <mml:mspace/> <mml:mtext>mSv</mml:mtext> </mml:mrow> </mml:math> which is higher than mean “E” of $$3.95\;{\text{mSv}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mn>3.95</mml:mn> <mml:mspace/> <mml:mtext>mSv</mml:mtext> </mml:mrow> </mml:math> observed for gated CT at $$80\;{\text{kV}}_{{\text{p}}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mn>80</mml:mn> <mml:mspace/> <mml:msub> <mml:mtext>kV</mml:mtext> <mml:mtext>p</mml:mtext> </mml:msub> </mml:mrow> </mml:math> . The average value of “E” for non-gated technique was observed less than that of gated technique at both $$100\;{\text{kV}}_{{\text{p}}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mn>100</mml:mn> <mml:mspace/> <mml:msub> <mml:mtext>kV</mml:mtext> <mml:mtext>p</mml:mtext> </mml:msub> </mml:mrow> </mml:math> and $$80\;{\text{kV}}_{{\text{p}}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mn>80</mml:mn> <mml:mspace/> <mml:msub> <mml:mtext>kV</mml:mtext> <mml:mtext>p</mml:mtext> </mml:msub> </mml:mrow> </mml:math> . The multiple regression analysis shows that “E” is significantly dependent on $${\text{DLP}}\left( {{\text{mGy}}\;{\text{cm}}} \right)$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mtext>DLP</mml:mtext> <mml:mfenced> <mml:mrow> <mml:mtext>mGy</mml:mtext> <mml:mspace/> <mml:mtext>cm</mml:mtext> </mml:mrow> </mml:mfenced> </mml:mrow> </mml:math> for both gated and non-gated techniques at 95% level of significance $$\left( {p &lt; 0.05} \right)$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mfenced> <mml:mrow> <mml:mi>p</mml:mi> <mml:mo>&lt;</mml:mo> <mml:mn>0.05</mml:mn> </mml:mrow> </mml:mfenced> </mml:math> . The Student’s t-test verifies that the mean value of “E” for both the techniques at $$100\;{\text{kV}}_{{\text{p}}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mn>100</mml:mn> <mml:mspace/> <mml:msub> <mml:mtext>kV</mml:mtext> <mml:mtext>p</mml:mtext> </mml:msub> </mml:mrow> </mml:math> and $$80\;{\text{kV}}_{{\text{p}}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mn>80</mml:mn> <mml:mspace/> <mml:msub> <mml:mtext>kV</mml:mtext> <mml:mtext>p</mml:mtext> </mml:msub> </mml:mrow> </mml:math> are significantly different at 95% level of significance $$\left( {p &lt; 0.05} \right)$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mfenced> <mml:mrow> <mml:mi>p</mml:mi> <mml:mo>&lt;</mml:mo> <mml:mn>0.05</mml:mn> </mml:mrow> </mml:mfenced> </mml:math> . Conclusions The effective dose received by pediatric patients is much higher when using ECG-gated acquisition with an average value of $$4.71\;{\text{mSv}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mn>4.71</mml:mn> <mml:mspace/> <mml:mtext>mSv</mml:mtext> </mml:mrow> </mml:math> and $$3.95\;{\text{mSv}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mn>3.95</mml:mn> <mml:mspace/> <mml:mtext>mSv</mml:mtext> </mml:mrow> </mml:math> at $$100\;{\text{kV}}_{{\text{p}}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mn>100</mml:mn> <mml:mspace/> <mml:msub> <mml:mtext>kV</mml:mtext> <mml:mtext>p</mml:mtext> </mml:msub> </mml:mrow> </mml:math> , and at $$80\;{\text{kV}}_{{\text{p}}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mn>80</mml:mn> <mml:mspace/> <mml:msub> <mml:mtext>kV</mml:mtext> <mml:mtext>p</mml:mtext> </mml:msub> </mml:mrow> </mml:math> respectively. Because low-voltage X-rays are more sensitive to high atomic number iodinated contrast media, the mean “E” for non-gated cardiac CT imaging at $$80\;{\text{kV}}_{{\text{p}}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mn>80</mml:mn> <mml:mspace/> <mml:msub> <mml:mtext>kV</mml:mtext> <mml:mtext>p</m

The Egyptian Journal of Radiology and Nuclear MedicineVol. 55(1)
Jawaharlal Nehru Medical College Hospital (IN), Aligarh Muslim University (IN)
Good health and well-being
Openalex Percentile: Top 16%
Radiation Dose and Imaging
1.62
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.