Prolonged exposure of implantable central venous access device salvaged by a simple local flap: A case report

Abstract Background An implantable central venous device is often used in patients when prolonged intravenous systemic therapy is anticipated for oncologic treatment. Exposure of a percutaneous implantable venous access device is a known complication that usually requires its removal. Methods We report a patient with a venous device implanted in the left arm, which was complicated by device exposure for 4 months. Clinically, there was no evidence of infection. The issue was addressed with a simple local flap for coverage. Results A local random fasciocutaneous flap was elevated under local anaesthesia and transferred to cover the exposed device as a day surgery. The wound healed uneventfully, with no recurrence of device exposure at the 3‐month follow‐up. Conclusion The reported case supports flap coverage as an effective method for addressing exposed implantable venous devices, even with prolonged exposure, provided there is no infection.

Authors

Institutions

Publication Details

Journal
Surgical Practice
Published
2024-09-26
DOI
https://doi.org/10.1111/1744-1633.12728
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Prolonged exposure of implantable central venous access device salvaged by a simple local flap: A case report

Peter San Ming Yu, Tam‐Lin Chow
Surgical Practice
Central Venous Catheters and Hemodialysis
article

Prolonged exposure of implantable central venous access device salvaged by a simple local flap: A case report

Peter San Ming Yu, Tam‐Lin Chow
article en

Abstract

Abstract Background An implantable central venous device is often used in patients when prolonged intravenous systemic therapy is anticipated for oncologic treatment. Exposure of a percutaneous implantable venous access device is a known complication that usually requires its removal. Methods We report a patient with a venous device implanted in the left arm, which was complicated by device exposure for 4 months. Clinically, there was no evidence of infection. The issue was addressed with a simple local flap for coverage. Results A local random fasciocutaneous flap was elevated under local anaesthesia and transferred to cover the exposed device as a day surgery. The wound healed uneventfully, with no recurrence of device exposure at the 3‐month follow‐up. Conclusion The reported case supports flap coverage as an effective method for addressing exposed implantable venous devices, even with prolonged exposure, provided there is no infection.

Surgical PracticeVol. 29(1)
United Christian Hospital (CN)
Openalex Percentile: Top 72%
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.