Closed‐form optimal solution of two‐degree‐of‐freedom system with Inerter based on equal modal damping with potential application in non‐structural elevator for seismic control

Abstract Targeting the great demand for adding non‐structural elevators to old residential buildings, this article proposes an updated configuration of tuned mass damper inerter (U‐TMDI) applied in external non‐structural elevators. An analog 2‐DOF system is established to describe the residential building controlled by an inerter elevator. Then, three closed‐form optimal solutions for designing the U‐TMDI are derived via the fixed‐point method, equal modal damping criterion, and the infinity damping assumption. Subsequently, these optimal solutions are compared and discussed involving the expressions of tuning frequency ratio and the optimal damping parameters, root locus diagram and supplemental damping ratios, transfer function, and robustness to frequency variation, respectively. Finally, a residential building example is adopted to validate the feasibility of the proposed retrofitting strategy and the closed‐form optimal design solutions. It is demonstrated that the optimal tuning frequency ratios derived by the fixed‐point method and equal modal damping criterion are different for U‐TMDI due to the influence of elevator stiffness ratio , while its degradation forms for tuned mass damper (TMD) are identical, recognizing the importance of the elevator stiffness. Moreover, the proposed retrofitting strategy of using an inerter elevator can significantly mitigate the main structure displacement by about 18%∼23% for both far‐field and near‐fault earthquakes.

Authors

Institutions

Publication Details

Journal
Earthquake Engineering & Structural Dynamics
Published
2024-09-26
DOI
https://doi.org/10.1002/eqe.4243
Citations
17
Primary Topic
Vibration Control and Rheological Fluids
Type
article
Field-Weighted Citation Impact
4.44

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Closed‐form optimal solution of two‐degree‐of‐freedom system with Inerter based on equal modal damping with potential application in non‐structural elevator for seismic control

Jia‐Lin Chen, Fei‐Fei Sun, Satish Nagarajaiah, Meng Wang et al.
17 citations
Earthquake Engineering & Structural Dynamics
Vibration Control and Rheological Fluids
4.44
article

Closed‐form optimal solution of two‐degree‐of‐freedom system with Inerter based on equal modal damping with potential application in non‐structural elevator for seismic control

Jia‐Lin Chen, Fei‐Fei Sun, Satish Nagarajaiah, Meng Wang, Xiuli Du
article en
17 citations

Abstract

Abstract Targeting the great demand for adding non‐structural elevators to old residential buildings, this article proposes an updated configuration of tuned mass damper inerter (U‐TMDI) applied in external non‐structural elevators. An analog 2‐DOF system is established to describe the residential building controlled by an inerter elevator. Then, three closed‐form optimal solutions for designing the U‐TMDI are derived via the fixed‐point method, equal modal damping criterion, and the infinity damping assumption. Subsequently, these optimal solutions are compared and discussed involving the expressions of tuning frequency ratio and the optimal damping parameters, root locus diagram and supplemental damping ratios, transfer function, and robustness to frequency variation, respectively. Finally, a residential building example is adopted to validate the feasibility of the proposed retrofitting strategy and the closed‐form optimal design solutions. It is demonstrated that the optimal tuning frequency ratios derived by the fixed‐point method and equal modal damping criterion are different for U‐TMDI due to the influence of elevator stiffness ratio , while its degradation forms for tuned mass damper (TMD) are identical, recognizing the importance of the elevator stiffness. Moreover, the proposed retrofitting strategy of using an inerter elevator can significantly mitigate the main structure displacement by about 18%∼23% for both far‐field and near‐fault earthquakes.

Earthquake Engineering & Structural DynamicsVol. 53(15)
Tongji University (CN), Beijing University of Technology (CN), Rice University (US)
National Natural Science Foundation of China
Openalex Percentile: Top 5%
Vibration Control and Rheological Fluids
4.44
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.