Interface Fatigue Test of Hybrid-Bonded Fiber-Reinforced Plastic-Reinforced Concrete Specimen

This research produced five hybrid-bonded fiber-reinforced plastic (HB-FRP)-reinforced beam specimens, and different fatigue load amplitudes were used as parameter variables for the fatigue performance tests of the FRP–concrete interface. The results show that FRP sliding with the number of cycles can be roughly divided into fatigue initiation stage, fatigue development stage, and fatigue damage stage, and finally, because the load is too large and friction, pin, and bonding cannot provide a greater inhibition effect, FRP adhesive length is not enough to withstand the stripping load and failure. FRP slip increases with increasing fatigue load amplitude for the same number of fatigue cycles; for the specimens with fatigue damage, the interfacial stiffness of FRP–concrete decreases with the increase in the number of cyclic, and the rate of stiffness damage at the FRP–concrete interface accelerates with increasing fatigue load amplitude. For fatigue load magnitudes higher than 0.6, the slopes of fatigue bond–slip curves decrease with the increase in the number of cycles. When the fatigue load magnitude is lower than 0.4, the slope of the fatigue bond–slip curve increases with the number of cycles and is close to the slope of the monotonically loaded curve. Due to the difference in load class, the bond strength of HB-F-1 continues to decrease with the increase in fatigue times, decreasing by 26% after 100 fatigue cycles and decreasing to 7.33 MPa after 5000 fatigue cycles. The bond strength of the sample HB-F-2 first increased and then decreased with the increase in fatigue times. After 10,000 fatigue cycles, the bond strength decreased by 8%, and at 11,133,300 fatigue breaks, the bond strength of the sample HB-F-3 continued to increase with the increase in fatigue times. At 2 million fatigue load cycles, the bond strength increased to 7 MPa, far from reaching the peak strength. The empirical formulas for the fatigue life curve of HB-FRP-reinforced specimens under single steel fasteners are proposed.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2024-09-26
DOI
https://doi.org/10.3390/buildings14103080
Citations
1
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.27
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Interface Fatigue Test of Hybrid-Bonded Fiber-Reinforced Plastic-Reinforced Concrete Specimen

Kun Zhou, Qian Wei, Chao Dong, Lei Gao et al.
1 citations
Buildings
Structural Behavior of Reinforced Concrete
0.27
article

Interface Fatigue Test of Hybrid-Bonded Fiber-Reinforced Plastic-Reinforced Concrete Specimen

Kun Zhou, Qian Wei, Chao Dong, Lei Gao, Zejun Zhang, Jiabin Wang, K. S. Fu, Ziqin Cheng
article en
1 citations

Abstract

This research produced five hybrid-bonded fiber-reinforced plastic (HB-FRP)-reinforced beam specimens, and different fatigue load amplitudes were used as parameter variables for the fatigue performance tests of the FRP–concrete interface. The results show that FRP sliding with the number of cycles can be roughly divided into fatigue initiation stage, fatigue development stage, and fatigue damage stage, and finally, because the load is too large and friction, pin, and bonding cannot provide a greater inhibition effect, FRP adhesive length is not enough to withstand the stripping load and failure. FRP slip increases with increasing fatigue load amplitude for the same number of fatigue cycles; for the specimens with fatigue damage, the interfacial stiffness of FRP–concrete decreases with the increase in the number of cyclic, and the rate of stiffness damage at the FRP–concrete interface accelerates with increasing fatigue load amplitude. For fatigue load magnitudes higher than 0.6, the slopes of fatigue bond–slip curves decrease with the increase in the number of cycles. When the fatigue load magnitude is lower than 0.4, the slope of the fatigue bond–slip curve increases with the number of cycles and is close to the slope of the monotonically loaded curve. Due to the difference in load class, the bond strength of HB-F-1 continues to decrease with the increase in fatigue times, decreasing by 26% after 100 fatigue cycles and decreasing to 7.33 MPa after 5000 fatigue cycles. The bond strength of the sample HB-F-2 first increased and then decreased with the increase in fatigue times. After 10,000 fatigue cycles, the bond strength decreased by 8%, and at 11,133,300 fatigue breaks, the bond strength of the sample HB-F-3 continued to increase with the increase in fatigue times. At 2 million fatigue load cycles, the bond strength increased to 7 MPa, far from reaching the peak strength. The empirical formulas for the fatigue life curve of HB-FRP-reinforced specimens under single steel fasteners are proposed.

BuildingsVol. 14(10)
Shandong University (CN), CCCC Highway Consultants (China) (CN)
Openalex Percentile: Top 43%
Structural Behavior of Reinforced Concrete
0.27
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.